background image

1

AUTOMATION SYSTEMS

GARAGE DOOR OPENER

Assembly instructions for the installer

V

ersion 1

DTM GO800

DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa
ul. Brzeska 7, 85-145 Bydgoszcz
tel./fax. (52) 340-15-83, 340-15-84
www.dtm.pl, [email protected]

Summary of Contents for DTM GO800

Page 1: ...GE DOOR OPENER Assembly instructions for the installer Version 1 DTM GO800 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Page 2: ...ply with the standards as well as with any applicable local regulations theymustcomplywiththerequirementsofEN12604 DTMSystemisnotresponsiblefortheconsequencesofdesigndefectsofthedrivenelementsorfor theirdeformationthatmayoccurduringuse Thewallsandceilingstowhichthedriveistobemountedmustbestrongandstable The installation must conform to the requirements of EN 12453 The safety level of the C D autom...

Page 3: ...afterthedriveis installedandconnectedtothemains Theradioremotecontrolmayonlybeusedwhenasafeforcevalueisset Theradioremotecontrolmayonlybeusedifitispossibletoobservethegatemovementandthere arenopeopleorobjectsinthemovementarea More information in European Union documents EN 12453 20017 10 Gates Safety of use of power operated doors Requirements and test methods EN 12604 2017 11 Gates Mechanicalaspe...

Page 4: ...ecessaryrepairs Do not attempt to repair or maintain the system yourself The system may only be serviced by qualifiedpersonnel Atleastevery6months theoperationoftheautomationsystem protectiondevicesandprotective circuitsshouldbecheckedbyqualifiedpersonnel Make sure that the persons who install maintain or operate the gate automation follow these instructions Keeptheseinstructionsinaplacewhereyouca...

Page 5: ...aftertime airing photoinputoperatingmodes stop reversewhenclosingorclosingandopening retractionofthetrolleyafterclosing yes 1 5mm 1 3Mechanicalcomponents Before starting work check if all the elements shown in fig 1 are present and then read the entire manual 2 MECHANICALASSEMBLY 2 1 Verification of the type and structure of the gate Inordertoproperlycompleteandinstalltheautomationsystem verifythe...

Page 6: ...eeded The actual force transmitted by the drive is influenced by gate type gate weight airmovementaroundthegate Low temperatures and high humidity may make it difficult or impossibletostarttheautomation Thedrivesarenotdesignedforcontinuousoperation themaximum operating frequency specified in the drive parameters must be maintained The gate must operate smoothly and without impact movement mustbesm...

Page 7: ...king conditions Measurethecenterofthegateandmarkitattheleafandlintelabovethegate Openthedoorslowlyanddeterminethesmallestdistancebetweenthemostprotrudingmovablepart ofthedoorandtheceiling THP Thisdimensionmustbeatleast35mm ThespacingbetweenTHPandthelower edgeoftheC railmustbeatleast5mmandupto65mm sothatthetrolleyarmwasatanangleof30 figure5 Close the gate and depending on the available space instal...

Page 8: ...drivehasnotbeenmoved fixthefittingtothegateleafusingself selectedfixingelements Fig 6C 7 Couplethetrolleywiththedoorbypullingthecable backward Thelevertowhichthecableisattached mustchangeitspositionfromverticaltohorizontal Fig 4 Initial assembly of the drive Fig 5 Definition of dimensions and recommended values A M10 14mm B 1 2 D 4xM6 C E 4xM6 THP the smallest distance between the top edge of the ...

Page 9: ...g it along the power line that may cause interference in the control signal Fig 6D If there are safety devices in the installation e g photocells emergency STOP buttonsetc installtheminaccordancewiththeirassemblyinstructions If there is no power socket it should be installed in accordance with the applicable standards at a distanceofabout0 5metersfromthecontrollerhousing Fig 6E 3 2 Connectingdevic...

Page 10: ...pory podczas pracy siłownika zatrzymuje lub zmienia kierunek Jeśli zainstalowane są urządzenia zabezpieczające np fotokomórki należy spowodować naruszenie fotokomórek i sprawdzić czy sterownik zareagował w odpowiedni sposób Tak samo postąpić w przypadku pozostałych urządzeńzabezpieczającychjeślizostałyzamontowane 4 3 Checkingthefunctionscontrollingthemovementoftheactuator Check that all devices es...

Page 11: ...in must be inspected annually and if the dirt is large it should be cleaned with a dry cloth We also inspect other elements of the automation system and check whether it works properly Thisiscriticaltoensuringlong term safeoperationofthesystem Especially control the security mechanisms Also unlock the drive and check that the gate is working properly Ifthegaterequiresit carryoutitsmaintenance Thed...

Page 12: ...12 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa Ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl ...

Reviews: