SECURITY OF IMPLEMENTATION OF THE AUTOMATION SYSTEM

 

Before starting the installation, carefully read the entire product installation and operation manual. 

Non-observance and non-compliance with the notes in this manual may lead to an accident in which people 
are injured or property damage occurs.
The gate drive ensures correct and safe operation only if the installation and use comply with the following 
safety rules. DTM System is not responsible for accidents resulting from improper use or unprofessional 
installation of devices.

 

The drive has an electronic obstacle detection mechanism. In order to ensure an adequate level of 

safety, the adjustment of the force should be performed with particular care.

·

Do not leave packaging materials within the reach of children, as they are potentially dangerous;

·

This product has been designed and manufactured solely for the intended use described in this 
documentation. Using it for any other purpose may adversely affect the technical condition and 
operation of the device and is a potential source of danger;

·

DTM System is not responsible for the consequences of improper use, not in accordance with the 
intended use;

·

The drive must be operated in a dry room;

·

Do not install the device in an environment with an increased risk of explosion or aggressive air;

·

If possible, install the drive at least 2.1 meters above the ground;

·

If a rail extension is installed on a heavy gate with the drive, use a second ceiling suspension;

·

The  half-open  gate  must  remain  in  this  position.  If  the  gate  moves  up  or  down,  it  must  be 
mechanically adjusted;

·

It is allowed to install the drive moved away from the symmetry axis of the gate if it does not cause 
deformation of the gate itself and allows the gate to move properly in the guides;

·

Automatic  swing  gates  should  comply  with  the  standards  as  well  as  with  any  applicable  local 
regulations, they must comply with the requirements of EN 12604;

·

DTM System is not responsible for the consequences of design defects of the driven elements or for 
their deformation that may occur during use;

·

The walls and ceilings to which the drive is to be mounted must be strong and stable;

·

The  installation  must  conform  to  the  requirements  of  EN  12453. The  safety  level  of  the C  +  D 
automated system is required;

·

Before starting any work on the system, disconnect all power sources;

·

The electrical installation to which the automation is connected must comply with the applicable 
standards and be properly made;

·

The installer should provide the device with a residual current device ensuring that the devices are 
cut off from the main power supply. The standards require a separation of the contacts of at least 
3mm in each pole (EN 60335-1). It is recommended to use a 6A thermal fuse with a circuit breaker for 
all circuits;

·

Take care to protect the power circuit with a differential switch with a threshold of 30mA;

·

Safety mechanisms (EN12978 standard) provide protection against the risks associated with the 
movement of moving mechanical parts, such as crushing, snagging or detachment;

·

DTM System is not responsible for the safety and efficient operation of the automation system in 
the event of using components that are not products offered by DTM System;

·

Only genuine parts should be used for servicing;

·

Do not modify the automation components in any way;

·

The end user should be informed about the method of handling, dealing with failures and about the 
dangers of using the automation system;

·

During the operation of the automation system, both children and adults must keep a safe distance 
from the operating automation;

·

The automation system can only be operated by properly trained adults

·

Control devices should be out of the reach of children in order to protect the automation system 
against accidental activation;

·

Movement through the gate is allowed only when it is fully open;

·

Service is only permitted by qualified personnel;

Summary of Contents for DTM GO800

Page 1: ...GE DOOR OPENER Assembly instructions for the installer Version 1 DTM GO800 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Page 2: ...ply with the standards as well as with any applicable local regulations theymustcomplywiththerequirementsofEN12604 DTMSystemisnotresponsiblefortheconsequencesofdesigndefectsofthedrivenelementsorfor theirdeformationthatmayoccurduringuse Thewallsandceilingstowhichthedriveistobemountedmustbestrongandstable The installation must conform to the requirements of EN 12453 The safety level of the C D autom...

Page 3: ...afterthedriveis installedandconnectedtothemains Theradioremotecontrolmayonlybeusedwhenasafeforcevalueisset Theradioremotecontrolmayonlybeusedifitispossibletoobservethegatemovementandthere arenopeopleorobjectsinthemovementarea More information in European Union documents EN 12453 20017 10 Gates Safety of use of power operated doors Requirements and test methods EN 12604 2017 11 Gates Mechanicalaspe...

Page 4: ...ecessaryrepairs Do not attempt to repair or maintain the system yourself The system may only be serviced by qualifiedpersonnel Atleastevery6months theoperationoftheautomationsystem protectiondevicesandprotective circuitsshouldbecheckedbyqualifiedpersonnel Make sure that the persons who install maintain or operate the gate automation follow these instructions Keeptheseinstructionsinaplacewhereyouca...

Page 5: ...aftertime airing photoinputoperatingmodes stop reversewhenclosingorclosingandopening retractionofthetrolleyafterclosing yes 1 5mm 1 3Mechanicalcomponents Before starting work check if all the elements shown in fig 1 are present and then read the entire manual 2 MECHANICALASSEMBLY 2 1 Verification of the type and structure of the gate Inordertoproperlycompleteandinstalltheautomationsystem verifythe...

Page 6: ...eeded The actual force transmitted by the drive is influenced by gate type gate weight airmovementaroundthegate Low temperatures and high humidity may make it difficult or impossibletostarttheautomation Thedrivesarenotdesignedforcontinuousoperation themaximum operating frequency specified in the drive parameters must be maintained The gate must operate smoothly and without impact movement mustbesm...

Page 7: ...king conditions Measurethecenterofthegateandmarkitattheleafandlintelabovethegate Openthedoorslowlyanddeterminethesmallestdistancebetweenthemostprotrudingmovablepart ofthedoorandtheceiling THP Thisdimensionmustbeatleast35mm ThespacingbetweenTHPandthelower edgeoftheC railmustbeatleast5mmandupto65mm sothatthetrolleyarmwasatanangleof30 figure5 Close the gate and depending on the available space instal...

Page 8: ...drivehasnotbeenmoved fixthefittingtothegateleafusingself selectedfixingelements Fig 6C 7 Couplethetrolleywiththedoorbypullingthecable backward Thelevertowhichthecableisattached mustchangeitspositionfromverticaltohorizontal Fig 4 Initial assembly of the drive Fig 5 Definition of dimensions and recommended values A M10 14mm B 1 2 D 4xM6 C E 4xM6 THP the smallest distance between the top edge of the ...

Page 9: ...g it along the power line that may cause interference in the control signal Fig 6D If there are safety devices in the installation e g photocells emergency STOP buttonsetc installtheminaccordancewiththeirassemblyinstructions If there is no power socket it should be installed in accordance with the applicable standards at a distanceofabout0 5metersfromthecontrollerhousing Fig 6E 3 2 Connectingdevic...

Page 10: ...pory podczas pracy siłownika zatrzymuje lub zmienia kierunek Jeśli zainstalowane są urządzenia zabezpieczające np fotokomórki należy spowodować naruszenie fotokomórek i sprawdzić czy sterownik zareagował w odpowiedni sposób Tak samo postąpić w przypadku pozostałych urządzeńzabezpieczającychjeślizostałyzamontowane 4 3 Checkingthefunctionscontrollingthemovementoftheactuator Check that all devices es...

Page 11: ...in must be inspected annually and if the dirt is large it should be cleaned with a dry cloth We also inspect other elements of the automation system and check whether it works properly Thisiscriticaltoensuringlong term safeoperationofthesystem Especially control the security mechanisms Also unlock the drive and check that the gate is working properly Ifthegaterequiresit carryoutitsmaintenance Thed...

Page 12: ...12 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa Ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl ...

Reviews: