DTM System DTM GO800 Assembly Instructions Manual Download Page 7

7

2.3. Stops and locks
 

Any  cables  or  loops  used  for  manual  opening  and  closing  of  the  gate  and  gate  blocking 

mechanisms should be removed, unless they are automatically activated by the drive!
2.4. Mechanical assembly
2.4.1. Initial assembly of the drive - preparation of the gearmotor for installation on the gate
 

Prepare the elements as shown in Fig. 1.

 

Assemble the rails in accordance with the drawing 4A, paying careful attention to their precise 

sliding with the connecting fittings.
 

Slip the front element on the rail and put the screw through it so that it can be "grabbed" on the 

other side with the help of a spring and a nut, fig. 4B. Using an appropriate socket wrench,

 screw in the 

screw until the toothed belt is tight

.

 

Referring to Figure 4C, mount the drive head to the rail, paying attention to the correct positioning 

of the drive shaft in the toothed belt pulley spline.
 

After mounting the drive head, you can proceed to install the ceiling hanger as shown in Fig. 4D. 

Other slings can be used if required, e.g. for a much higher mounting surface.
 

In a correctly assembled rail with a V-belt, find the lower part of the trolley and screw the trolley part 

with the unlocking mechanism to it, Fig. 4E. Also attach the cable to help unlock the drive.

2.4.2. Installation of the drive and manual control of working conditions

 

Measure the center of the gate and mark it at the leaf and lintel above the gate.

 

Open the door slowly and determine the smallest distance between the most protruding movable part 

of the door and the ceiling - THP. This dimension must be at least 35 mm. The spacing between THP and the lower 
edge of the C-rail must be at least 5 mm and up to 65 mm (so that the trolley arm was at an angle of 30 °, figure 5.
 

Close the gate and, depending on the available space, install the drive to the lintel. Trace horizontally, 

symmetrically, two holes at a distance of 16 mm from the gate axis each and 20-80 mm above the THP, as shown 
in Fig. 5. Drill, depending on the type of substrate, with a 10 mm drill bit in concrete or 5 mm diameter in wood.
 

Fasten the front handle of the drive to the lintel prepared in this way, Fig. 6A [1] (using expansion 

bolts, etc. - so that the fixing ensures a sufficient level of safety. These activities should be entrusted to a 
qualified person with the necessary experience). Then, using the pin and cotter pin, connect the front of the 
rail to the handle, Fig.6A [2].
 

Then, using e.g. a ladder (suitably solid and stable), initially level the drive.

 

If necessary, release the trolley by pulling down once on the emergency release mechanism, Fig. 6C [1]. 

Move the trolley back and open the gate.
 

Position  the  ceiling  hanger  approx.  300  mm  from  the  controller  housing  (depending  on  the  door 

structure and the ceiling, the hanger can be mounted in the range from 0 to 600 mm relative to the controller 
housing, Fig. 6B).

Rys. 3.

 Materiały i narzędzia niezbędne przy montażu zestawu.

Mechanical assembly

5mm

10mm

10mm

13mm

14mm

14mm

2x

2x

Summary of Contents for DTM GO800

Page 1: ...GE DOOR OPENER Assembly instructions for the installer Version 1 DTM GO800 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Page 2: ...ply with the standards as well as with any applicable local regulations theymustcomplywiththerequirementsofEN12604 DTMSystemisnotresponsiblefortheconsequencesofdesigndefectsofthedrivenelementsorfor theirdeformationthatmayoccurduringuse Thewallsandceilingstowhichthedriveistobemountedmustbestrongandstable The installation must conform to the requirements of EN 12453 The safety level of the C D autom...

Page 3: ...afterthedriveis installedandconnectedtothemains Theradioremotecontrolmayonlybeusedwhenasafeforcevalueisset Theradioremotecontrolmayonlybeusedifitispossibletoobservethegatemovementandthere arenopeopleorobjectsinthemovementarea More information in European Union documents EN 12453 20017 10 Gates Safety of use of power operated doors Requirements and test methods EN 12604 2017 11 Gates Mechanicalaspe...

Page 4: ...ecessaryrepairs Do not attempt to repair or maintain the system yourself The system may only be serviced by qualifiedpersonnel Atleastevery6months theoperationoftheautomationsystem protectiondevicesandprotective circuitsshouldbecheckedbyqualifiedpersonnel Make sure that the persons who install maintain or operate the gate automation follow these instructions Keeptheseinstructionsinaplacewhereyouca...

Page 5: ...aftertime airing photoinputoperatingmodes stop reversewhenclosingorclosingandopening retractionofthetrolleyafterclosing yes 1 5mm 1 3Mechanicalcomponents Before starting work check if all the elements shown in fig 1 are present and then read the entire manual 2 MECHANICALASSEMBLY 2 1 Verification of the type and structure of the gate Inordertoproperlycompleteandinstalltheautomationsystem verifythe...

Page 6: ...eeded The actual force transmitted by the drive is influenced by gate type gate weight airmovementaroundthegate Low temperatures and high humidity may make it difficult or impossibletostarttheautomation Thedrivesarenotdesignedforcontinuousoperation themaximum operating frequency specified in the drive parameters must be maintained The gate must operate smoothly and without impact movement mustbesm...

Page 7: ...king conditions Measurethecenterofthegateandmarkitattheleafandlintelabovethegate Openthedoorslowlyanddeterminethesmallestdistancebetweenthemostprotrudingmovablepart ofthedoorandtheceiling THP Thisdimensionmustbeatleast35mm ThespacingbetweenTHPandthelower edgeoftheC railmustbeatleast5mmandupto65mm sothatthetrolleyarmwasatanangleof30 figure5 Close the gate and depending on the available space instal...

Page 8: ...drivehasnotbeenmoved fixthefittingtothegateleafusingself selectedfixingelements Fig 6C 7 Couplethetrolleywiththedoorbypullingthecable backward Thelevertowhichthecableisattached mustchangeitspositionfromverticaltohorizontal Fig 4 Initial assembly of the drive Fig 5 Definition of dimensions and recommended values A M10 14mm B 1 2 D 4xM6 C E 4xM6 THP the smallest distance between the top edge of the ...

Page 9: ...g it along the power line that may cause interference in the control signal Fig 6D If there are safety devices in the installation e g photocells emergency STOP buttonsetc installtheminaccordancewiththeirassemblyinstructions If there is no power socket it should be installed in accordance with the applicable standards at a distanceofabout0 5metersfromthecontrollerhousing Fig 6E 3 2 Connectingdevic...

Page 10: ...pory podczas pracy siłownika zatrzymuje lub zmienia kierunek Jeśli zainstalowane są urządzenia zabezpieczające np fotokomórki należy spowodować naruszenie fotokomórek i sprawdzić czy sterownik zareagował w odpowiedni sposób Tak samo postąpić w przypadku pozostałych urządzeńzabezpieczającychjeślizostałyzamontowane 4 3 Checkingthefunctionscontrollingthemovementoftheactuator Check that all devices es...

Page 11: ...in must be inspected annually and if the dirt is large it should be cleaned with a dry cloth We also inspect other elements of the automation system and check whether it works properly Thisiscriticaltoensuringlong term safeoperationofthesystem Especially control the security mechanisms Also unlock the drive and check that the gate is working properly Ifthegaterequiresit carryoutitsmaintenance Thed...

Page 12: ...12 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa Ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl ...

Reviews: