GATE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
GATE 1
NORMAL
OPERATION
RESET/
DISCONNECT
NORMAL
OPERATION
RESET/
DISCONNECT
1
ADJUSTMENT
» LEARN LIMITS
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal
system.
• NEVER increase force beyond minimum amount required to close gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also
need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested.
Gate MUST reverse on contact with a rigid object.
If a mistake is made during programming and you would like to start over:
Toggle the RESET switch on the operator.
The programming times-out automatically after 60 seconds of inactivity.
LEARN LIMIT INTRODUCTION
The limits are internal settings that indicate when the gate is in the fully open
position and the fully closed position. For proper functionality, the limits must be
programmed during the installation process. The gate has to travel a minimum of
6 feet in order to program the limits.
The programming uses a combination of buttons on the control board. The specific
buttons used for programming depends on which side of the gate the primary
operator is installed and how many operators the installation includes.
BEFORE programming the limits ensure that the gate is closed and the
chain is connected to the operator. To close the gate press the reset switch to
RESET/DISCONNECT, then manually close the gate. To resume normal operation
press the reset switch back to NORMAL OPERATION.
1
15