background image

Owners Copy: SAVE THESE INSTRUCTIONS for future reference

MS65MYQ

Sectional Garage Door Opener

Installation and Operating Instructions

This manual contains IMPORTANT SAFETY information

DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY

gomerlin.com.au
gomerlin.co.nz

Commander Essential

Summary of Contents for Merlin MS65MYQ

Page 1: ...eference MS65MYQ Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY gomerlin com au gomerlin co nz Commander Essential ...

Page 2: ...or similarly qualified persons in order to avoid hazard This opener should not be installed in a damp or wet space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer Failure to comply with the following instructions may result in serious personal injury or property da...

Page 3: ...y in place supported entirely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If your door binds sticks or is out of balance call a trained door technician DOOR TYPES A Sectional Door with curved track To suit spring balanced Residential Sectional doors up to 13 5 m2 1 Elect...

Page 4: ...rton contains the opener its fitting hardware and accessories The rail carton contains the rail and some hardware Rails Different length rails 2 2 m 2 4 m are available for different height doors ensure you have the correct one 2 RAIL SIZES AVAILABLE 3 NOTE The Ceiling Fixing Point Standard is the position of the hanging bracket measured back from the lintel see item 1 to 7 of completed installati...

Page 5: ... procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 10 4x 9 8x 8 4x 7 1x 6 1x 1 1x 2 1x 3 4x 4 4x 5 4x HARDWARE PROVIDED Drill Bits 10 TOOLS REQUIRED 4 5 6 1 Clevis pin 80 mm Section 12 2 R clip Section 12 3 Hexagonal head screw Sections 14 16 4 Nut M8 Sections 14 16 5 Flat washer M8 Sections 14 16 6 Clevis Pin Se...

Page 6: ...destrian doors are installed within a garage door Terminals 4 5 are normally linked If the link is removed the opener will not operate Remove the link and install a Safety switch to prevent the opener from activating the garage door when the built in pedestrian door is open Terminals are designed for operationg with a dry contact automatic sensing switch such as model SW02 or similar Door Safe con...

Page 7: ...e tightening to compress the spring and remove all the slack in the belt DO NOT OVERTIGHTEN but ensure belt is firm 3 36 38 mm as indicated in the diagram is normal 3 4 2 A 1 5 1 Slide the RAIL BRACKET 1 onto the powerhead end of the rail A around 200 mm 2 Position the rail drive spocket 2 over the opener motor shaft 3 and push down to install 3 Secure the rail on the opener with two C Rail bracke...

Page 8: ...ow the header bracket Use foam packing material as a protective base NOTE If the door spring is in the way youʼll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and secure with the 80 mm clevis pin and R clip 1 item 1 in the Hardware Provided Section 5 and 2 it...

Page 9: ...between door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively parallel to the horizontal door panels 13 Disengage the trolley mechanism see section Operating the manual release and slide it back towards the powerhead Secure the hanging push arm up into the rail as...

Page 10: ... Item 4 in Hardware Provided Section 5 HANG THE OPENER 14 The opener must be securely fastened to a sound structural support above the opener 1 Postion the opener as in the previous step Check the rail is centred over the door Ensure the rail brackets fig 1 is on the Powerhead end of the rail in a position as close to the opener as possible X 2 If mounting directly onto the ceiling fig 2 screw the...

Page 11: ...d see figure 3 Unscrew the front two screws in the trolley assembly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL RELEASE The manual release mechanism enables the door to be manually operated during power outages or in an emergency The RED Manual Release cord is preassembled to the trolley When the opener is installed the h...

Page 12: ... the door is in the desired UP position press and release the PROG Button The DOWN Arrow Button will begin to flash figure 4 4 Press and hold the DOWN Arrow Button until the door is in the desired DOWN position figure 5 NOTE The UP and DOWN Arrow Buttons can be used to move the door up and down as needed 5 Once the door is in the desired DOWN position press and release the PROG Button The UP Arrow...

Page 13: ...se test When the door reverses off the 40 mm obstacle remove the obstacle and run the opener through a complete travel cycle Door must not reverse in closed position If it does repeat Program the Limits and Force then repeat safety reverse test 1 40 mm high The safety reverse system test is important Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor Failure to proper...

Page 14: ... section THE PROTECTOR SYSTEMTM IR BEAMS OPTIONAL To prevent entrapment install The Protector System IR Beams no higher than 100 mm above the floor Disconnect power to the garage door opener before installing The Protector System IR Beams 20 21 PROGRAM TRANSMITTERS TO THE OPENER LIGHT To Program your transmitters to operate your garage door opener light follow the below steps 1 Press and release t...

Page 15: ...on Keep clear of the IR Beams and check the door closes after the preset time To Deactivate TTC 1 Enter into TTC Activation mode by pressing both PROG and DOWN buttons together for 3 seconds figure 2 Release when the courtesy light flashes twice 2 Press and release the PROG button to save figure 4 courtesy light will flash once TTC is now deactivated Indicator LED Indicator LED Door Fully Closed f...

Page 16: ...ther for 3 seconds figure 3 The Courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all transmitter codes as in the Wireless programming section will also delete this feature PARTIAL OPENING FEATURE PET Indicator LED Indicator LED Door Fully Closed figure 1 figure 3 or 25 1 service www m m B B A 2 114A3361 For Service Call Installation Date 3 132A2900 RISK OF ENTR...

Page 17: ...ARN button on the garage door opener 2 Press and release the yellow LEARN button The LED indicator light will glow steadily 3 Enter a 4 digit personal identification number PIN of your choice on the keypad 4 Press and hold the ENTER button Check to see if the opener light flashes Release the ENTER button after the light flashes To change an existing keyless entry PIN 1 Enter the existing programme...

Page 18: ...perate door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjustments Once a Year Lightly grease the belt and inside the rail assembly where the trolley slides Internally the opener does not require additional lubrication Lightly grease the belt and i...

Page 19: ...rved arm 041A4036 Centre Rail bracket RAIL HARDWARE 31 18 ACCESSORIES 6 5 7 4 760E E1702M 774ANZ 8 9 3 1 2 10 827AU 1 Model E138M Wireless wall button 2 Model E960M 4 Channel transmitter 3 Model E940M 1 Channel visor transmitter 4 Model E943M 3 Channel visor transmitter 5 Model E945M 3 Channel mini transmitter 6 Model E840M Keyless entry system 7 Model 774ANZ The Protector SystemTM 8 Model E1702M ...

Page 20: ...er Cord 026B0181 041A4004 Passpoint Assembly 041A4024 Transformer 041A0046 Logic Board PCB Housing Control Cover assembly 041A0007 LED Module 041A1805 Lens Cover 041A4033 Motor Assembly 041A1804 1 Brand Cover 041A0010 Chassis Cover RAIL REPLACEMENT PARTS 041A4017 1 Motor shaft adapter 041A4021R Trolley latch belt 041A4016R Position tab belt 041A0034 Transfer Board 32 ...

Page 21: ... especially on excessively heavy doors check the Motor Shaft Adapter has not stripped 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic code on next page 1 Opener doesn t operate from either door control or transmitter Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are c...

Page 22: ...or correct as needed The Protector System IR Beams are misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internally the possible cause may b...

Page 23: ...P and DOWN direction Electronic Automatic force adjustment Electrical Transformer overload protector and low voltage push button wiring Limit Device Mechanical Passpoint RPM sensor Limit Adjustment Electronic Soft start Soft stop Dimensions Length Overall 3 24 m Headroom Required 30 mm Hanging Weight 11 kg Receiver Memory Registers 64 handset codes 4 keypad devices 1 code each Operating Frequency ...

Page 24: ...land consumer protection laws with respect to major failures Chamberlain or its Professional Dealer will provide you with either repairs to the Unit or a replacement Unit Repairs and replacement parts provided under this Chamberlain Limited Warranty are provided free of charge and are warranted for the remaining portion of the original warranty period This Chamberlain Limited Warranty provides ben...

Reviews: