Safety Features
WARNING
Do not use the lift with any safety devices inoperative !!!
Emergency Stop Button
Serves to disconnect the lift in case of emergency.
Main Switch
Serves to turn the lift ON and OFF.
When in position 0 the switch can be padlocked (also see Lockout/Tag out
Procedure in Maintenance Instructions).
Control Elements
D
EAD
M
AN
T
YPE
C
ONTROL
The operator is required to hold the switch/button in the engaged position to raise/lower the lift.
C
ABLE
R
EMOTE
C
ONTROL
B
UTTONS
The buttons are flush mounted to avoid inadvertent actuation.
Locking Device
The locking device serves to prevent inadvertent lowering motions of the lift
caused by gear, load nut or lifting screw failures. The carriage is blocked by
safety wedge (1) and counterwedge (2).
Electric Drive Motor
The motors are equipped with electrically actuated brakes (plus manual
override). Once the motors are turned off, the brakes engage and prevent any
further lift movements.
Thermal Overload Protection
Overload protection via electronically monitored thermo-switches.
Warning and Information Labels
SAFETY INSTRUCTIONS
Do not change or remove the warning and information labels. Order replacement if
damaged, missing or illegible !!!
CLM16
IOM.
DOC
5/8/09
Summary of Contents for CLM16
Page 10: ...Specifications CLM16 IOM DOC 5 8 09...
Page 21: ...SMA 2H Standard Carriage Wide Body Carriage CLM16 IOM DOC 5 8 09...
Page 22: ...SMA 2 Standard Carriage CLM16 IOM DOC 5 8 09 Wide Body Carriage...
Page 33: ...Lower Limit Switch CLM16 IOM DOC 5 8 09...
Page 43: ...Column Base Frame Height 2 CLM16 IOM DOC 5 8 09...
Page 45: ...Column Cover CLM16 IOM DOC 5 8 09...
Page 47: ...Dolly CLM16 IOM DOC 5 8 09...
Page 49: ...Drive Assembly CLM16 IOM DOC 5 8 09...
Page 51: ...Carriage Standard CLM16 IOM DOC 5 8 09...
Page 53: ...Universal CLM16 IOM DOC 5 8 09...