Maintenance
Sensors
Speed Measurement
Proximity switch B3 – used for speed measurement – is located in a threaded hole at the worm gear
unit (1). Use the inspection hole (2) to check for correct adjustment of the proximity switch.
Adjusting Proximity Switch B3:
Set a clearance of 5/64" between
proximity switch and outer edge of
castle nut.
Clearance can be checked via
inspection hole using a feeler gauge.
Gear box casing removed.