Motor
1) Remove the cover of motor junction box.
2) Verify the jumper setting corresponds to the
line voltage.
3) Reinstall cover of motor junction box.
Motor Cable
Motor Cable
#1 #2 #3
#1 #2 #3
CLM16
IOM.
DOC
5/8/09
For 208/230 V, three jumpers
must be set vertically.
For 440/480 V, two jumpers must be set
horizontally in the lower row of terminals.
Final Checkout Procedure
Visually check the columns for shipping damage.
Run the lift through several full cycles.
Ensure that all controls are operating correctly.
Ensure that carriages are synchronized during the up and down movements.
Operational Test
Load the lift with a vehicle appropriate for this lift.
Run the lift through several full cycles.
Ensure that all controls are operating correctly.
Ensure that carriages are synchronized during the up and down movements.