ENGLISH
This hydraulic tool is powered by a 14.4V battery and is quiet in operation with minimal
vibration.
The residual battery capacity level is automatically displayed after every cycle.
BATTERY OPERATED HYDRAULIC CRIMPING TOOL
B135LN-C ; B135LN-CA
1. GENERAL CHARACTERISTICS
3
32
B135LN-CA
suitable for installing electrical compression connectors
for conductors up to 400 mm
2
(800 MCM)
130 (14.6)
700 (10,000)
424 x 94 x 302 (16.7 x 3.7 x 11.9)
“C” shaped with large jaw opening 42 mm (1.65") see Fig. 1
14.4
AGIP ARNICA 32 or SHELL TELLUS TX 32 or equivalent.
the tool has a twin speed operation and automatically
switches from a rapid advancing speed of the ram
to a slower, more powerful crimping speed.
the tool is equipped with a maximum pressure valve.
-15°C to +40°C (+5°F to +104°F)
Application range:
Crimping force
kN (sh ton):
Rated operating pressure bar (psi):
Dimensions LxWxH mm
(inches):
Weight with battery
kg (lbs):
Head:
Motor Volt
DC:
Battery
Volt / Ah:
Battery charger supply
Volt / Hz:
Recommended oil:
Operating speed:
Safety:
Operating temperature:
Acoustic Noise (Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u)
– The weighted continuous acoustic pressure level equivalent
A at the work place L
pA
is equal to .................................................................................75 dB (A)
– The maximum value of the weighted acoustic displacement
pressure C at the work place L
pCPeak
is ..................................................................... < 130 dB (C)
– The acoustic power level emitted by the machine
L
WA
is equal to .............................................................................................................85,3 dB (A)
Risks due to vibration (Directive 2006/42/EC, annexe 1, point 2.2.1.1)
Tests carried out in compliance with the indications contained in UNI ENV 25349 and UNI EN 28662
part 1
st
Standards, and under operating conditions much more severe than those normally found,
certify that the weighted root mean square in frequency of the acceleration the upper limbs
are exposed to for each biodynamic reference axis does not exceed 2.5 m/sec
2
.
TOOL TYPE:
B135LN-C
220 - 240 / 50 - 60
120 / 50 - 60
TABLE 2 - TABLEAU 2 - TABELLE 2 -
TABLA 2 - TAVOLA 2
64
60
60
204
203
202
05
13
14
15
53
53
53
53
57
57
58
58
59
59
67
68
69
72
72
72
72
73
76
80
11
17
18
18
18
18
20
21
23
26
29
32
47
47
70
70
70
70
71
06
25
28
16
22
19
23
7,8 (17.2)
8,1 (17.9)
14.4 / 3.0 Li-Ion