background image

SMS Text & Android Application for various programming 
Telephone Numbers Entry & SMS Controls 
Telephone Number Redial Times 
Telephone Number Display - ON / OFF 
Voice Message Recording for playing on Telephone calls during Intrusion - Optional 
Wireless Sensors, Remotes & Panic Keys Registering/Deletion 
Wireless Sensor 

– Operating Mode 

Wired Zones 

– Operating Mode 

Wired Zones Programmable Delay 
Wired Zones Sensing Delay 
Precautions 
Trouble Shooting 
Technical Specifications 
Terms of Warranty 
Index of - Wireless Sensor Numbers & their corresponding Names 

Note:  

-

 

Copper Connections Pvt. Ltd reserves the right to alter equipment specifications and descriptions contained herein 
and make no commitment to update or keep current the information herein.  

      All information herein is subject to change at any time without notice. No part of this publication shall be deemed to  
     be part of any contract or commitment whatsoever.   

-

 

Product  specifications  and  features  are  subject  to  changes  without  prior  notice  due  to  our  constant  endeavor  to 
improve the product. 

 

  .

                                                                                                   

Features

                                                                                           

.

 

Auto Detect Open Door 

       When the system is being ARMED, if any door having Magnetic Switch (Wired or Wireless) is open, the system will  
      alert the user with a intermittent Siren Sound. The same is true for all wired sensors.  
      During this time, if the Opened Sensor or the opened Wired Zone is closed, the system will get ARMED and the  
      intermittent Siren sound will stop. 
      The main Panel display in this case is explained under 

the heading “Display explanations” – sub heading “while  

      

Arming the system”. 

Always Armed Zones 

   

Some sensors can be configured to work 24 Hours. Whether the system is ARMED or not, these sensors would  

   initiate Siren hooting and Telephone dialing.   
   For example, a heat detector can be placed near Generator so that whenever generator heats due to a fault, the  
   siren would alert the user & also inform on his Cell number. 
   For further details refer 

the heading “Wireless Sensor – Operating Mode” and “Wired Sensor – Operating Mode” 

Auto ARM / DISARM - Day Wise

 

   System can be programmed to ARM / DISARM at 3 different sets of timings for each day of the week. User can also  
   

enter up to 10 Holidays in the system. On those days the system continues in the previous day’s status  

   Example: If the user has off days on Saturday and Sunday then the system can be programmed to remain ARMED  
                  on these 2 days. And for rest of the week the system will ARM & DISARM at the set time. For further  
                  

details refer the heading “Auto Arm / Disarm Time” 

ARM Bypass

 

        User has option to ARM all the Zones or selected Zones. This helps in ARMING the system while servants are  
        present in some part of the building. 

For further details refer the heading “ARM Bypass” 

Auto Dialer

 

(Dialing through GSM SIM during intrusion) 

         The system dials up to 6 Telephone numbers and plays siren sound (pre-recorded message-Optional), during 
         intrusion. 

After 10 secs of Siren Sound, it plays the message “Batt low, Wired Zone Open, Wireless Sensor  

         

Number, etc” 

         Each Telephone number can be programmed to dial from 1 to 15 times. 
         

For further details refer the headings ”Telephone Numbers Entry” + “Telephone Number Redial Times” +   

         

“Telephone Number Display - ON / OFF”

 

Battery

 

(Rechargeable)

 

In-built Li rechargeable batteries

 

for

 

backup lasting up to 15 hours. Can be extended by  

         connecting optional BAS-PS (Power Supply with 12V 7AH Maintenance Free Battery). 

Battery Low warning 

– of Main Unit 

         When the in-built Batteries of the Main Unit goes low & the SYSTEM is in ARMED condition, it will dial the pre-fed  
        

Telephone number to inform the user with a Voice Message “Battery is Low”. It is possible to Listen-in and Disarm  

        the system through Telephone.  
        In case the system is DISARMED then displ

ay will show “Main Batt is low” & it will give a beep every 15 secs. In  

        this condition, the display back light keeps getting ON for 10 secs and then OFF for 10 secs.  
        Note: When Battery goes low and the system is ARMED, intrusion will not work. 

Battery Low warning 

– of Wireless Magnetic / Vibration Sensors (MSW, VSW, VSW-T, PIRW, PIRW-T) 

        When the cell of any of the wireless Magnetic / Vibration Sensors goes low & the system is in ARMED condition,  
        it will dial the pre-fed 

Telephone number to inform the user with a Voice Message “Battery is Low + ID Number”.  

        The user can Disarm the system & can also Listen-in.  
        When a new Cell is restored in the Sensor, the system registers that the sensor is now operative. 

Summary of Contents for BAS-G

Page 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Page 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Page 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Page 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Page 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Page 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Page 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Page 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Page 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Page 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Page 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Page 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Page 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Page 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Page 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Page 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Page 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Page 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Page 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Page 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Page 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Page 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Page 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Page 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...