background image

                                                     
                                         
                                                  
                                    
                         
 
                
              

    Date

:

 DD/MM/YY 

    Time

:

 HH:MM in 24 Hours format 

    Tel

:

 X (X= no of Tel Numbers stored) 

    Wired Zones Active

:

 X (No of Wired Zones  

              that are Enabled out of 8 Wired Zones) 
    Wireless Sensor

:

 X (No of Wireless Sensors  

                             Registered, except Remotes) 
   Remote

:

 X (No of Remotes registered)

 

5  System details – Detailed 

XXXX+SYS  DETAIL          
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

System will send SMS giving following details

:

 

    System Status

:

 ARMED or DISARMED 

    Power

:

 On Mains / On Battery 

    W STAT

:

 This shows the Modes in which 8  

                  Wired Zones are Enabled. DS  
                  means Disabled. NA= Normal ARM, 
                  AA= Always ARM, TR= Traitor, BA= 
                  By Pass, 
     WL Stat

:

 This shows the ID, Type and Mode  

                   of the registered wireless sensors. 
                  MS= Magnetic Switch, VIBR=  
                  Vibration Sensor, RMT= Remote,  
                  PIR= Motion Sensor, TAMP=  
                  Tamper Sensor, PAN= Panic,  
                  HEAT= Heat Detector, SMK=  
                  Smoke Detector, GAS = GAS  
                  Detector, HHW= Heat and Humidity  
                  Detector, BEAM= Beam Sensor,  
                  WKBD= Wireless Key Board, M+S=  
                  Magnetic Sensor with Switch 
                   DS means Registered but Disabled.  
                  NA= Normal ARM, AA= Always  
                  ARM, TR= Traitor, BA=By Pass.

 

6  Registered telephone 

number list 

XXXX+TEL 
 

All  the  registered  Telephone  numbers  will  be       
listed.

 

7  Change Master Password 

CHANGE   PW   XXXX   YYYY 
 

XXXX = old Master Password , YYYY = New Master 
Password 

8  SIM balance check 

SIMBAL  ccccc 
 
 

ccccc = Service provider’s SIM balance code. E.g. for 
Airtel , it is *123#. 

You will get a SMS stating the 

balance in SIM of BAS.

 

9  Add telephone number 

XXXX+ATELjk  ttttttttt 
 
 

j = Tel location from 1-6 , k = E for SMS commands 
enable/ D for SMS commands disable , tttttttt = 
telephone number (max 11 digits)  

10  Delete telephone number 

XXXX+DTELj 

j = tel location from 1 – 6 

11  Set auto Arm/Disarm 

XXXX+AUTOj   aaaa  dddd 
 
 

j = group number (1 -3) , aaaa = arm time in 24hr 
format , dddd= disarm time in 24hr format. This 
setting will be applied for all the 7 days of the week. 

12  Disable auto Arm/Disarm 

XXXX+OFFAUTO 

 Auto ARM/DISARM will be disabled. 

13  Delete all wireless sensors 

XXXX+WLALLDEL 

 All Wireless Sensors will be deleted. 

14  Delete specific wireless 

sensor 

XXXX+WLDEL  nn 
 

nn= wireless ID to delete.  

15  Add wireless sensor 

XXXX+WLADD  nn  y 
 

nn=wireless ID, y = type of sensor. Refer table below 
for values.  

16  Change mode of specific 

wireless sensor 

XXXX+WLMOD  nn  y 
 

nn = wireless ID , y = mode of sensor( 0=Normal Arm 
, 1 = Disable, 2= arm bypass , 3 = always armed)  

17  Disable all wired zones 

XXXX+WRALLDIS 

 All Wired Zones will be disabled. 

18  Set mode of specific wired 

zone 

XXXX+WRMOD  n  y 
 
 

n = wired zone (1 to 8), y = mode of zone ( 0=Normal 
Arm , 1 = Disable, 2= arm bypass , 3 = traitor mode, 4 
= always armed)  

19  Set name of wired zone 

XXXX+WNAMEn  pppp 

n = wired zone (1 to 8), p= name of wired zone (up to 
15 characters). This name will be used in SMS sent to 
users & CMS. 

20  Set name of first eight 

wireless sensor 

XXXX+WLNAMEn  pppp 

n = wireless sensor (1 to 8), p= name of wireless 
sensor (up to 15 characters). This name will be used 
in SMS sent to users & CMS. 

Summary of Contents for BAS-G

Page 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Page 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Page 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Page 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Page 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Page 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Page 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Page 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Page 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Page 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Page 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Page 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Page 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Page 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Page 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Page 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Page 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Page 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Page 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Page 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Page 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Page 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Page 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Page 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...

Reviews: