                   Enter Master Password (1234) + # 
                   

Keep Pressing 2 to select “V Recrdng” 

                   Press # 
                   Press 1 

       Now start speaking near the Mic of the Main Unit. The recording starts when the display shows 10 and  
                   ends at 1 i.e., total 10 secs of recording. 

                   Press #  + Quick Exit 

Programming for Playback of recorded message: 

                   

Press  “

SET

” 

                   Enter Master Password (1234) + # 
                   

Keep Pressing 2 to select “V Recrdng” 

                   Press # 
                   Press 2 

       Listen to the recorded message. The play back starts when the display shows 10 and ends at 1. 

                   Press #  + Quick Exit 

Note:

 When this option is not taken, the system plays a Siren Sound in its place. 

 

.

                             Wireless Sensors, Remotes & Panic Keys Registering/Deletion                      

.

 

Maximum 75 Wireless Sensors (including Wireless Remotes & Signal repeaters) and unlimited Wireless Sirens can be 
used in a system.                     

 

Every Wireless Sensor / Remote / Panic has a unique security code & has to be registered in the Main Unit in order to 
make it functional. 
Process: Press “SENSOR” key 

  Enter Master Password (1234) + # 
  Press 1 

              Keep Pressing 2 to select Type of Sensor to be registered. See the List below. 

                      

             Wireless Sensor Type      Display in case of Intrusion

 

                                  Magnetic Snsr             MS          (In case of MS without Switch) 
                                                                    MS+SW   (In case of MS with Switch) 
                                  Vibratn Snsr                VIBRN 
                                  Remote                       RMT 

           PIR                             PIR 

                                  Tamper                       TAMP 

           Panic Remote             PAN 

                                  Heat Detector             HEAT 
                                  Smoke Detectr           SMOKE 
                                  Gas Detector              GAS 
                                  Heat/Humidity             HHW (In default Temperature = 50 Deg Cent &  
                                                                                  Humidity = 97%. To change these values  
                                                                                  refer the HHW Manual.) 
                                  Beam Sensor              BEAM 
                                  

Wireless Kbrd             “Not Applicable” (It is shown as KBD in History)  

                                  Flashing Sir

n

               

“Not Applicable” 

              

Press #  (In case of Magnetic Sensor, there will be another option to select “MS Widout Swch” or “MS with  

                            

Switch”. Press 1 for “Widout Swch” and 2 for “MS with Switch”. Magnetic Sensor with switch is  

                            designed for applications where the door is opened / closed frequently during the day thereby  
                            consuming too much of the battery of the sensor.)  
              Dial 01 to 75 (ID number to be given to the sensor. An ID number cannot be entered twice in a system.) 
              Press #  

  Now trigger the Wireless sensor (either Open the Sensor or Close the sensor) + #  Quick Exit 
                  

In case of “Wireless Keyboard”

:

 

                         

Press 2 + Pass Word of the “Wireless Key Board” + # 

Note:

 Whenever the intrusion take place, the Main Unit display will show the ID number of the Sensor and its Name. 

          For example: If a Magnetic Wireless Sensor is installed on the Main Door and is registered with N= 3 + ID 
                               number = 11, then the display will show WL11: MS.  Here, WL stands for Wireless & MS for  
                               Magnetic Sensor. 

        :

 During triggering of the Wireless sensor (either Open the Sensor or Close the sensor), two short beeps in the  

          

Main Unit confirms a successful setting & display shows  “Successfully Sensed”. 

          

Five short beeps means a wrong setting & display shows “This Zone ID is already allocated”. 

        

:

 

During the programming, the system auto cancels the operation if it doesn’t receive the input from Wireless  

          Sensor within 20 seconds. 
        

:

 Smoke, Heat, Heat/Humidity, Signal Repeater, GAS & Tamper Type 

automatically gets registered in “Always  

          

ARMED” mode and cannot be hanged to any other mode except to DISABLE mode. 

Deletion of Single Wireless Sensor registration 

To delete a Wireless Sensor registration from the Main Unit: 
                   

Press  “

SENSOR

” 

                   Enter Master Password (1234) + # 
                   Press 2 + 2 
                   Press UP or DOWN key to select the Sensor ID that is to be deleted. 

Summary of Contents for BAS-G

Page 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Page 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Page 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Page 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Page 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Page 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Page 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Page 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Page 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Page 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Page 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Page 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Page 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Page 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Page 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Page 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Page 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Page 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Page 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Page 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Page 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Page 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Page 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Page 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...

Reviews: