background image

21  Set system name 

XXXX+SYSNAME  qqqq 

q= name of system (up to 15 characters). This name 
will be used in SMS sent to users & CMS. 

22  To Force Arm System 

XXXX+FOARM  

Arms the system even if a sensor is left open.  

23  Date & Time setting 

XXXX+DATE  ddmmyy   j  hhmm 
 

dd = date, mm=month , yy=year , j = day 
(Mon=1…Sun=7), hh=hours, mm = minutes 

24  No. of rings to pick up 

incoming call 

XXXX+RINGS  n 
 

n= number of rings to be assigned (1 to 8) 

25  Sensors Open 

XXXX+OPEN  SENS 

Displays all the sensors which are open 

26  System reset 

XXXX+RESETSYS 
 

All data will be erased except the Telephone 
Numbers and their SMS configuration. 

Note:

 Messages are case sensitive. Enter in 

Capital letters only

       

:

 XXXX in the above table refers to 4 digit Password 

 

Programming by Android Application: 

The free android application named ‘BAS-G’ is available on Google Play Store. 
Steps to add your BAS-G panel in the application are as follows: 
         

Press ‘LOGIN’ displayed on home screen of app 

         

Press ‘ADD’ 

         Enter System Name- a suitable name for the BAS-G System 
         Enter System Number- the number of SIM Card installed in BAS-G 
         

Press ‘DONE’ 

The system name will now be displayed on the app.  
Similarly, multiple s

ystems can be added by pressing the ‘ADD’ option on top right corner 

         On pressing the name, you are shown options to Arm, Disarm, By Pass Arm, etc. 
         Press the desired option, and enter your password for the BAS-G panel.  
         For all 

other programming, press ‘Settings’, choose the desired programming, and enter your password to  

         Confirm 
         A confirmation SMS for the same will be received from the panel. 
 

Wireless Sensor Type Table 

Type 

Code 

Type 

Code 

MS 

SMOKE 

VSW 

GAS 

RMT 

HHW 

PIR 

BEAM 

TAMP  4 

KBD 

PANIC  5 

MS+SW 

HEAT 

  

  

 

.

                                                        

Telephone Numbers Entry & SMS Controls                                           

.

 

User  can  enter  up  to  6  telephone  numbers  that  can  be  dialed  by  the  system.  Each  Telephone  number  can  be 
individually configured for

:

 

            Sensing & receiving SMS in selected events only. 
You can set a Telephone number for SMS in all events (i.e., ARM, DISARM, PANIC, Batt. Low,  Tamper, Intrusion, etc 
+  user  can  send  SMS  from  that  Telephone  number  to  ARM,  DISARM,  Change  Pass  Word,  etc).  After  setting  the 
Telephone  number  for  all  events,  you  can  disable  selected  events.  Similarly  you  can  Disable  all  events  and  enable 
selected events. 

To enter Telephone numbers that are to be dialed during intrusion: 

Press  Key “3”  
Enter Master Password (1234) + #  
Press “UP” or DOWN” to select the telephone number. 
Press # + Back Space 
Enter the Telephone number (Whenever Country code is used, make sure to add + before the country   
                                            

code. “+” can be added through “

” Key). 

                        Each Telephone number can be of maximum 16 digits.   

Press # 
Quick Exit 
Press “UP” or DOWN” to set the next /previous Telephone number in location 1 to 6. 
Repeat the above steps for all the Telephone numbers 

To configure Telephone numbers for SMS to be sent / received in all events or in NO event: 

Press  Key “3”  
Enter Master Password (1234) + #  
Press “UP” or DOWN” to select the telephone number. 

Summary of Contents for BAS-G

Page 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Page 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Page 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Page 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Page 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Page 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Page 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Page 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Page 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Page 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Page 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Page 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Page 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Page 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Page 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Page 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Page 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Page 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Page 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Page 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Page 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Page 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Page 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Page 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...

Reviews: