background image

                 heading 

“Wired Sensor – Operating Mode” 

Operation

:

 Whenever, the Sensor is triggered irrespective of the system being in ARMED or DISARMED condition, the  

                 Siren will starts hooting

 

and the system will dial out the Telephone numbers 

 

.

                                                                                                   

Arm 

                                                                                                  

.

 

You  can  ARM  the  system  and  leave  the  Remote  inside  the  premises,  if  required.  In  this  case  close  all  the  sensors, 
ARM  the  system.  Now  leave  the  premises  within  10  secs  and  close  the  door.  This  10  secs  can  be  decreased  or 
increased up to 60 secs. Refer heading “Delay to ARM” for changing this time.  
 
While moving out of the premises, ARM the system by any of the following method: 
     

Press “QUICK EXIT” & 

 Key together on the Main Unit + Enter Master Password 234) + # 

                    or 
     

Press the “ARM” on the Wireless Remote. 

Caution: While Arming the system from Remote, the system gives 2 Loud Confirmation tones. If 2 tones  are  
              not heard, arm it again. Keep pressing the ARM key until you are sure of the 2 tones. 

In ARM state, the indicator on the main unit would glow RED.  
Now, whenever any sensor is triggered, the system will dial the preset telephone number and activate the siren after 10 
secs. 
Note

:

 In case of PANIC button being pressed, there is no delay. 

 

 

.

                                                                                        

ARM Bypass 

                                                                                           

.

 

In this mode, one  or more Zones can be programmed to remain Disarmed while  rest of the Zones  get  ARMED. This 
feature is useful where some part of the building occupied by servants may be left Disarmed while keeping the rest of 
the building Armed.  
Procedure to activate the system in Bypass mode is explained below.  
If system is Armed normally through, then even the Bypass zones get Armed. 
To program a Zone as a Bypass Zone refer “Wireless Sensor – Operating Mode” & “Wired Zones – Operating Mode”.

 

To ARM the system in Bypass mode:  
      

Press “Back Space” and  “7” together on the Main Unit. 

      Enter Master Password 

”1234” + # 

                    or 
      

Press the “ARM Bypass” Key on the Wireless Remote. 

Caution:

 While Bypass Arming the system, the system gives 2 Loud Confirmation tones. If 2 tones  are not heard, arm  

               it again. Keep pressing the Bypass ARM key until you are sure of the 2 tones. 
 

.

                                                         

ARM / DISARM Confirmation Sounds control                                       

.

 

Whenever the system is ARMED / DISARMED there are 2 Sound indications: 
    Siren Sound Confirmation 
    Voice Command Confirmation 
Both these can be switched ON/OFF as explained below. 

Siren Sound Confirmation  

When the system is ARMED or DISARMED from Wireless Remote or the Main Unit, there is a confirmation sound from 
the Siren. This Sound can be set as ON or OFF.  
Press  SET 
Enter Master Password (1234) + #  
Keep Pressing 2 to select “Conf Tone” 
Press # 
Press 

key “

UP

 

or “

DOWN

  to select 

OFF

 or 

ON

 for this feature 

Press  # + Quick Exit 

Voice Command Confirmation  

When the system is ARMED or DISARMED from Wireless Remote, there is a confirmation Voice Command which can 
be set as ON or OFF.  
Programming

:

 

   Pre

ss  “

SET” 

   Enter Master Password (1234) + #  
   

Keep Pressing 2 to select “Rmt Voice Cnf” 

   Press # 
   

Press key “

UP

 

or “

DOWN

  to select ON or OFF 

   Press # + Quick Exit 

If it is set at OFF, the Voice Command will not appear while Arming / Disarming from the wireless Remote. 

Note:

 This cannot be switched OFF while Arming / Disarming from the Main Unit.

 

 

.

                                                                   

Auto Arm / Disarm Time + Holidays                                               

.

 

The system can be programmed to ARM and DISARM automatically up to 3 times a day. 
There are 3 groups of time and each group has a time of ARM and DISARM.  
Programming

:

 

   

Press  “

SET” 

Summary of Contents for BAS-G

Page 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Page 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Page 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Page 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Page 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Page 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Page 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Page 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Page 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Page 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Page 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Page 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Page 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Page 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Page 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Page 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Page 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Page 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Page 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Page 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Page 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Page 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Page 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Page 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...