67
②
Remote Display Connection (CD-SERIES)
Connect the C/L Port on the back side of the Indicator to the 2 PIN connector of the
Remote display as shown below:
C/L1
ㅇ
--------------------------
ㅇ
1 Receive Data
C/L2
ㅇ
--------------------------
ㅇ
2 Signal Ground
C/L Terminal
2 PIN Connector (Female)
Indicator’s C/L Port 2 PIN Connector of the Remote Display
2) Data format
①
Communication Rate: 1,200 bps – 115,200 bps
(Set at the F23 set value)
②
Data bit: 8, Stop bit: 1, Parity bit: None
Data bit: 7, Stop bit: 1, Parity bit: Even #/odd #
(Set at F21 Parity Bit set value)
③
Code : ASCII
④
When data is sent to computer?
(Set at F22 Communication Data Set-up)
⑤
Transmission Data Format (set at F24 output format)
* 22 byte of CAS
.
.
.
DATA (8byte
)
CR LF
└─┘
└──┘
│
└──────┐
│
└──┘
US(Unstable) GS(GROSS weight) Device ID Lamp condition byte Empty Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)
- Device ID : Transmit 1 byte so that the receiver can receive data selectively which indicator
sent.(Device ID is selected in F23 .)
- Byte for Status Lamp
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1 Stable 1 Hold Print Net Tare Zero
* 10 byte of CAS
DATA (8byte
)
CR
LF
* 18 byte of AND
.
.
DATA (8byte
)
CR LF
└─┘
└──┘
└──┘
US(Unstable) GS(GROSS weight) Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)
Summary of Contents for CI-502A
Page 1: ... 2 ...
Page 9: ... 10 External Appearance and Dimensions External Appearance CI 502A CI 505A ...
Page 10: ... 11 Dimensions of the Product CI 502A CI 505A ...
Page 11: ... 12 Front Panel Descriptions CI 502A CI 505A ...
Page 27: ... 28 9 th Step Item MovebacktotheWeighingMode ...
Page 67: ... 68 Weight Data 8 byte a 13 5kg 1 3 5 b 135kg 1 3 5 c 135kg 1 3 5 ...
Page 74: ... 75 Sealing Method Sealing 1 Sealing the Indicator Sealing the Load Cell Connector ...
Page 83: ... 84 MEMO ...
Page 84: ... 85 MEMO ...
Page 85: ... 86 MEMO ...
Page 86: ... 87 MEMO ...
Page 87: ... 88 ...
Page 88: ... 89 ...