![CAS CI-502A Owner'S Manual Download Page 22](http://html1.mh-extra.com/html/cas/ci-502a/ci-502a_owners-manual_2565929022.webp)
`
23
CAL 3: The step of Zero Calibration.
Function: Zero Calibration
Key used
Display
Sub-Display
Description
: Zero
Calibration
: Finish
UnLoAd
----
Good
CAL 3
Zero 1728
Clear the scale and press
.
During Zero Calibration
Zero Calibration complete.
Automatically move to the
Span Calibration menu after
this display.
Note 1. If the Zero Calibration is successful without error, a 'Good' message is displayed and
it automatically moves to the Setting Weight Menu for Span Calibration (CAL 4).
Note2. If the Zero value is too low or high, an error message 'Err 33' or 'Err 34' is displayed.
Note3.
If you wish to only perform a Zero Calibration, then clear the scale and press
Press the Zero Key: Zero Calibration, Press the Clear key: escape from Zero Calibration
CAL 4: Setting Weight Step
Function: Setting Balance Weight during Span Calibration
(Range: 1 ~ 99,999)
Key used
Display
Sub-Display
Description
: Save and/or
move to the next menu
~
: Change the value
: Enter a
decimal(.)
L5000
L 500
CAL 4
Set SPAn
5000 kg
500 kg
Note 1. Initially, 100% of the maximum weight is given, but if the known weight of the
balance weight is different, then re-enter the desired weight value.
If the resolution of the balance weight is less than 1/5,000, then set it above 10%, and
if the resolution is over 1/5,000, then set it above 20% in order to measure the most
accurate weight.
Note 2. Do not enter the sum amount of the balance weight on the scale and the weight to be
on scale. Enter the amount of weight to be put on the scale excluding the weight
already on the scale.
Note 3. If the set weight is less than the maximum weight by 2%, then Err 32 is displayed.
Summary of Contents for CI-502A
Page 1: ... 2 ...
Page 9: ... 10 External Appearance and Dimensions External Appearance CI 502A CI 505A ...
Page 10: ... 11 Dimensions of the Product CI 502A CI 505A ...
Page 11: ... 12 Front Panel Descriptions CI 502A CI 505A ...
Page 27: ... 28 9 th Step Item MovebacktotheWeighingMode ...
Page 67: ... 68 Weight Data 8 byte a 13 5kg 1 3 5 b 135kg 1 3 5 c 135kg 1 3 5 ...
Page 74: ... 75 Sealing Method Sealing 1 Sealing the Indicator Sealing the Load Cell Connector ...
Page 83: ... 84 MEMO ...
Page 84: ... 85 MEMO ...
Page 85: ... 86 MEMO ...
Page 86: ... 87 MEMO ...
Page 87: ... 88 ...
Page 88: ... 89 ...