246
LEGEND
Local Access to the UPC Open Controller
The user can use a BACview
6
handheld keypad display unit or
the Virtual BACview software as a local user interface to an
Open controller. These items let the user access the controller
network information. These are accessory items and do not
come with the UPC Open controller.
The BACview
6
unit connects to the local access port on the
UPC Open controller. See Fig. M. The BACview software
must be running on a laptop computer that is connected to the
local access port on the UPC Open controller. The laptop will
require an additional USB link cable for connection.
See the
BACview Installation and User Guide
for instructions
on connecting and using the BACview
6
device.
To order a BACview
6
Handheld (BV6H), consult Commercial
Products i-Vu Open Control System Master Prices.
Fig. M — BACview
6
Device Connection
APPENDIX F
—
BACNET COMMUNICATION OPTION (CONT)
Table M — Open System Wiring Specifications and Recommended Vendors
WIRING SPECIFICATIONS
RECOMMENDED VENDORS AND PART NUMBERS
Wire Type
Description
Connect Air
International
Belden RMCORP
Contractors
Wire and Cable
MS/TP
Network (RS-485)
22 AWG, single twisted shielded pair, low capacitance, CL2P,
TC foam FEP, plenum rated. See MS/TP Installation Guide for
specifications.
W221P-22227
—
25160PV
CLP0520LC
24 AWG, single twisted shielded pair, low capacitance, CL2P,
TC foam FEP, plenum rated. See MS/TP Installation Guide
for specifications.
W241P-2000F
82841
25120-OR
—
Rnet
4 conductor, unshielded, CMP, 18 AWG, plenum rated.
W184C-2099BLB 6302UE
21450
CLP0442
AWG
—
American Wire Gage
CL2P
—
Class 2 Plenum Cable
CMP
—
Communications Plenum Rated
FEP
—
Fluorinated Ethylene Polymer
TC
—
Tinned Copper
Summary of Contents for WeatherExpert 48N2
Page 135: ...135 Fig 18 48 50N Typical Power Schematic Nominal 075 Ton Unit Shown ...
Page 136: ...136 Fig 19 48 50N Typical Power Schematic Nominal Ton 90 150 Units Shown ...
Page 137: ...137 Fig 20 48 50N Main Base Board Input Output Connections ...
Page 138: ...138 Fig 21 48 50N RXB EXB CEM Input Output Connections a48 9307 ...
Page 139: ...139 Fig 22 48 50N EXV SCB Input Output Connections a48 9308 ...
Page 140: ...140 Fig 23 48N Typical Modulating Gas Heat Unit Control Wiring ...
Page 141: ...141 Fig 24 50N Typical Electric Heat Unit Control Wiring ...
Page 144: ...144 Fig 27 48N Typical Gas Heat Section Wiring Nominal Ton 120 to 150 Units ...
Page 145: ...145 Fig 28 48 50N Typical Power Component Control Wiring 460 v ...
Page 146: ...146 Fig 29 48 50N Component Control Wiring 575 v Nominal Ton 075 to 150 Units ...
Page 147: ...147 Fig 30 48 50N Component Arrangement Power Box ...
Page 148: ...148 Fig 31 48 50N Component Arrangement Control Box ...
Page 240: ...240 APPENDIX D VFD INFORMATION CONT Fig G VFD Bypass Wiring Diagram WHEN USED ...