KGAET0201ETK: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

12

L13F009

Fig. 9 – Vent Located Below Floor with Upflow Furnace and Through-the-Cabinet Venting

L13F010

Fig. 10 – Vent Located Below Horizontal Furnace

Representative drawing only, some models may vary in appearance

TO CODE--APPROVED DRAIN

OR CONDENSATE PUMP

F

D & E

FLOOR

JOISTS

G

B

H

USE MEDIA CABINET ADAPTER OR

CONSTRUCT AN ADAPTER BOX

(FURNACE CANNOT BE SET ON

FLOOR DUE TO SERVICEABILITY)

AIR FLOW

CONFIGURATION FOR VENT AND

/

OR COMBUSTION AIR PIPIING

(See NOTES in Figure 1)

COMBUSTION AIR INLET PIPE MAY TERMINATE IN

WELL VENTILATED CRAWL SPACE (VENTILATED

COMBUSTION AIR) OR EXTERNAL TO STRUC

-

TURE. TRAP KIT MAY ALSO BE APPLIED.

SLOPE UP TO

TERMINATION

1/4-

IN. PER FOOT

Two inch pipe shown.
When another size pipe is
used, discard the 2-in. tee
in the kit and use a field
supplied tee that is the
same diameter as the pipe
being used.

Representative drawing only, some models may vary in appearance

TO CODE--APPROVED DRAIN

OR CONDENSATE PUMP

F

D & E

FLOOR JOISTS

G

B

H

CONFIGURATION FOR VENT AND

/

OR COMBUSTION AIR PIPIING

(See NOTES in Figure 1)

AIR FLOW

SLOPE UP TO

TERMINATION

1/4-

IN. PER FOOT

Two inch pipe shown.
When another size
pipe is used, discard
the 2-in. tee in the
kit and use a field
supplied tee that is
the same diameter as
the pipe being used.

Summary of Contents for KGAET0201ETK

Page 1: ...r Follow the manufacturer s instructions in the use of primer and cement and never use primer or cement beyond its expiration date The safe operation as defined by ULC S636 of the vent system is based...

Page 2: ...rainage system and possibly the living space See Fig 3 Application to Combustion Air Inlet Piping Systems This Trap Kit may used to help prevent liquid moisture from the inlet piping system from enter...

Page 3: ...be either away from trap vent side or toward trap combustion air side curve of vent tee must be positioned toward termination toward major flow of condensate except as shown in Fig 2 i When larger di...

Page 4: ...t and transition to the pipe diameter required in the vertical portion of the pipe after the tee WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow these warnings could result in personal inju...

Page 5: ...d listed to ULC S636 3 Not all materials below may be approved or listed to ULC S636 4 Royal Pipe and IPEX are approved suppliers of ULC S636 pipe fittings cements and primers 5 Factory accessory conc...

Page 6: ...PLUG THESE PORTS A OPEN DOWNFLOW ORIENTATION B PLUG THESE PORTS A OPEN HORIZONTAL RIGHT ORIENTATION A OPEN B PLUG THESE PORTS HORIZONTAL LEFT ORIENTATION Representative drawing only some models may va...

Page 7: ...llations must comply with regulations of local building heating plumbing or other codes in effect in area where installation is made Complete the installation of the drainage system as follows 1 Dry f...

Page 8: ...te 7 Listen for gurgling noises in the venting and drainage systems This is an indication that there are dips in the piping system or that the traps are not operating properly Correct the conditions a...

Page 9: ...g doors and windows and all doors between the space in which the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dr...

Page 10: ...y in appearance H G SLOPE UP TO TERMINATION 1 4 IN PER FOOT Two inch pipe shown When another size pipe is used discard the 2 in tee in the kit and use a field supplied tee that is the same diameter as...

Page 11: ...ISTS G B A AIR FLOW H SLOPE UP TO TERMINATION 1 4 IN PER FOOT Two inch pipe shown When another size pipe is used discard the 2 in tee in the kit and use a field supplied tee that is the same diameter...

Page 12: ...PIPIING See NOTES in Figure 1 COMBUSTION AIR INLET PIPE MAY TERMINATE IN WELL VENTILATED CRAWL SPACE VENTILATED COMBUSTION AIR OR EXTERNAL TO STRUC TURE TRAP KIT MAY ALSO BE APPLIED SLOPE UP TO TERMIN...

Page 13: ...rnace L12F029 Fig 12 Combustion Air and Vent Pipe Diameter Transition Location and Elbow Configuration Representative drawing only some models may vary in appearance TO CODE APPROVED DRAIN OR CONDENSA...

Page 14: ...rrier Company Edition Date 04 20 Catalog No AG KGAET 06 Replaces AG KGBET 01 KGAET0201ETK Installation Instructions Manufacturer reserves the right to change at any time specifications and designs wit...

Reviews: