KGAET0201ETK: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

relié à l’installation conforme aux instructions ci- haut mentionnées. Le

standard Canadien recommande l’ inspection par un personel qualifié et

ce, une fois par année.
Les  autoritées  ayant  juridiction  (inspecteurs  de  gas,  inspecteurs  en

bâtiments,  département  des  incendies,  etc)  devraient  être  consultées

avant l’installation afin de déterminer si un permis est requis. 

INTRODUCTION

This instruction covers the installation of the External Vent Trap Kit with

the furnaces listed in Table 1. This kit may be applied to either or both

the  vent/exhaust  piping  system  and/or  the  combustion-air  inlet  piping

system.
Very  high  efficiency  gas  furnaces  tend  to  condense  nearly  all  of  the

water vapor products of combustion within the furnace. Since there is

less water vapor to condense in the venting system, extra care must be

given  to  verifying  that  the  drain  trap(s)  will  self-prime  under  normal

conditions. IT IS IMPERATIVE that these instructions be followed fully

to ensure proper operation of the venting drainage system.

Table 1 – Allowed Gas Furnaces

DESCRIPTION AND USAGE

Use this External Vent Trap Kit (“Trap Kit”) to allow the furnace venting

system  to  be  positioned  below  the  level  of  the  furnace.  In  this

configuration, the condensate from the venting system does NOT drain

to the furnace (see 

Table 1

).

This Trap Kit may also be used for the combustion air inlet piping, either

by  itself,  or  in  conjunction  with  the  Trap  Kit  being  applied  to  the

vent/exhaust piping. When used for the combustion air inlet piping, only,

the venting system must be installed as shown in the furnace installation

instructions.
This External Vent Trap Kit (“Trap Kit”) contains the following items:

Application to Vent/Exhaust Piping Systems

The venting system is configured such that ALL of the venting system is

sloped  toward  the  Trap  Kit,  and  therefore,  all  of  the  vent  system

condensate  is  directed  to  the  Trap  Kit.  The  Internal  Drain  Trap  Plug

MUST  BE  APPLIED  to  the  vent  side  of  the  collector  box  trap

connection of the furnace to prevent vent gasses from being introduced

into the drainage system, and possibly the living space. See 

Fig. 3

.

Application to Combustion Air Inlet Piping 

Systems

This Trap Kit may used to help prevent liquid moisture from the inlet

piping system from entering the furnace. The Trap Kit may be used on

the inlet piping side, even if a Trap Kit is not used on the venting side

(see 

Fig. 1

, 

Fig. 2

 and 

Fig. 8

)  and the Furnace installation instructions

for  more  information  on  the  application  of  the  Trap  Kit  on

combustion-air inlet piping systems. 

Fig. 8

  shows  the  Trap  Kit  applied  in  upflow  applications  for

combustion-air inlet piping. The Trap Kit may be applied in any furnace

orientation-upflow,  downflow,  horizontal.  The  Trap  Kit  should  be

located  as  close  as  possible  to  the  furnace.  If  the  Trap  Kit  is  applied

ONLY to the combustion air inlet piping system, the vent/exhaust piping

should be configured as shown in the furnace installation instructions,

NOT these instructions.

WARNING

!

CARBON MONOXIDE POISONING HAZARD

Failure  to  follow  these  warnings  could  result  in  personal  injury  or

death.

The Internal Drain Trap Plug MUST BE APPLIED to the vent side of

the collector box trap connection of the furnace. Failure to do this may

result in vent gasses being released into the living space.

Failure  to  use  a  properly  constructed  trap(s),  applying  the  incorrect

trap(s),  or  NOT  water-priming  trap(s)  before  operating  furnace  may

allow positive pressure vent gases to enter the structure through drain

tube.  Vent  gases  contain  carbon  monoxide  which  is  tasteless  and

odorless.

USE WITH:

35” Furnaces

(excluding Ultra Low NOx)

External Condensate Drain Trap

1

Trap-Tee Vent Fitting (2-in./50mm PVC)

1

Internal Drain Trap Plug

1

NOTICE

!

OPTIONAL CONFIGURATION FOR COMBUSTION 

AIR INLET PIPE

In applications where there is a risk of excessive moisture entering the

combustion air inlet pipe, a moisture trap may be added to the inlet pipe

to help prevent moisture from entering the furnace from the combustion

air inlet pipe. 

When sizing venting systems, the equivalent length of the optional inlet

pipe moisture trap must be taken into account.

CAUTION

!

UNIT OPERATION HAZARD

Failure to follow this caution could result in intermittent unit operation.
When  used,  install  the  Trap  Kit  at  the  lowest  point  of  the

combustion-air  inlet  piping  system,  within  24–in.  (0.6  M)  of  the

furnace. This  will  help  prevent  water  build-up  in  the  combustion-air

inlet piping, and help prevent erratic unit operation.

Summary of Contents for KGAET0201ETK

Page 1: ...r Follow the manufacturer s instructions in the use of primer and cement and never use primer or cement beyond its expiration date The safe operation as defined by ULC S636 of the vent system is based...

Page 2: ...rainage system and possibly the living space See Fig 3 Application to Combustion Air Inlet Piping Systems This Trap Kit may used to help prevent liquid moisture from the inlet piping system from enter...

Page 3: ...be either away from trap vent side or toward trap combustion air side curve of vent tee must be positioned toward termination toward major flow of condensate except as shown in Fig 2 i When larger di...

Page 4: ...t and transition to the pipe diameter required in the vertical portion of the pipe after the tee WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow these warnings could result in personal inju...

Page 5: ...d listed to ULC S636 3 Not all materials below may be approved or listed to ULC S636 4 Royal Pipe and IPEX are approved suppliers of ULC S636 pipe fittings cements and primers 5 Factory accessory conc...

Page 6: ...PLUG THESE PORTS A OPEN DOWNFLOW ORIENTATION B PLUG THESE PORTS A OPEN HORIZONTAL RIGHT ORIENTATION A OPEN B PLUG THESE PORTS HORIZONTAL LEFT ORIENTATION Representative drawing only some models may va...

Page 7: ...llations must comply with regulations of local building heating plumbing or other codes in effect in area where installation is made Complete the installation of the drainage system as follows 1 Dry f...

Page 8: ...te 7 Listen for gurgling noises in the venting and drainage systems This is an indication that there are dips in the piping system or that the traps are not operating properly Correct the conditions a...

Page 9: ...g doors and windows and all doors between the space in which the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dr...

Page 10: ...y in appearance H G SLOPE UP TO TERMINATION 1 4 IN PER FOOT Two inch pipe shown When another size pipe is used discard the 2 in tee in the kit and use a field supplied tee that is the same diameter as...

Page 11: ...ISTS G B A AIR FLOW H SLOPE UP TO TERMINATION 1 4 IN PER FOOT Two inch pipe shown When another size pipe is used discard the 2 in tee in the kit and use a field supplied tee that is the same diameter...

Page 12: ...PIPIING See NOTES in Figure 1 COMBUSTION AIR INLET PIPE MAY TERMINATE IN WELL VENTILATED CRAWL SPACE VENTILATED COMBUSTION AIR OR EXTERNAL TO STRUC TURE TRAP KIT MAY ALSO BE APPLIED SLOPE UP TO TERMIN...

Page 13: ...rnace L12F029 Fig 12 Combustion Air and Vent Pipe Diameter Transition Location and Elbow Configuration Representative drawing only some models may vary in appearance TO CODE APPROVED DRAIN OR CONDENSA...

Page 14: ...rrier Company Edition Date 04 20 Catalog No AG KGAET 06 Replaces AG KGBET 01 KGAET0201ETK Installation Instructions Manufacturer reserves the right to change at any time specifications and designs wit...

Reviews: