66
80HMA
Alarm
code
Item
Product type
Failure when
Type
Master Board - Comfort Module
40
Temperature/Humidity sensor of User
Interface in zone 1
Single zone
Value out of range and
User Interface In Zone.
Par.107: 1
A
41
Comfort Module Tank Temperature
sensor failure [TWB]
Comfort Module /
2-Zone Kit
Value out of range
B
42
Leaving Water Temperature Sensor
failure
Comfort Module /
2-Zone Kit
Sensor
Value out of range
B
43
Domestic Hot Water temperature
sensor failure
Any
- The DHW Temperature
value is out of range
OR
Domestic Hot Water
! !Q
- Par.71:1 or 2 and the sensor
B
44
Outdoor temperature sensor failure
Comfort Module /
2-Zone Kit
Outdoor Air Temperature
- the value is out of range or
or
- Outdoor Air Temperature
or
Outdoor Air Temperature
Sensor from communicating
Heat Pump not available
A
45
Flowswitch 1
Any
#&
Case 1:
- Water Pump Output not
- DHW-V is not active
- Heat Pump is ON
Æ
#&
Case 2:
- Water Pump Output not
- Heat Pump is ON
- Par.81: 1
Æ
#&
Case 3:
- Water Pump Output is
- Water Pump Output is ON
Æ
#&
B;D
46
Flowswitch 2
Comfort Module /
2-Zone Kit
#&
Case 1:
- Water Pump Output not
- Heat Pump is OFF
Æ
#&
Case 2:
- Water Pump Output not
- Heat Pump is ON
- DHW-V is active
- Par.81: 0
Æ
#&
Case 3:
- Water Pump Output is
- Water Pump Output is OFF
Æ
#&
B;D
47
Communication with Master User
Interface
Comfort Module
When Master Board did
not receive data from user
interface within 3 minutes
B