Table 4–6 DataCORDER Pre-Trip Result Records
TEST NO.
TITLE
DATA
1-0
Heater On
Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1
Heater Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0
Condenser Fan On
Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/
Closed, Change in currents for Phase A, B and C
2-1
Condenser Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0
Low Speed Evaporator Fan On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1
Low Speed Evaporator Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0
High Speed Evaporator Fan On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1
High Speed Evaporator Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0
Supply/Return Probe Test
Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1
Secondary Supply Probe (SRS)
Test
Pass/Fail/Skip
5-2
Secondary Return Probe (RRS)
Test
Pass/Fail/Skip
6-0
Discharge Thermistor Test
Pass/Fail/Skip
6-1
Suction Thermistor Test
Pass/Fail/Skip
6-2
Discharge Pressure Sensor Test
Pass/Fail/Skip
6-3
Suction Pressure Sensor Test
Pass/Fail/Skip
6-4
Compressor Current Draw Test
Pass/Fail/Skip
6-5
Compressor Leak Test
Pass/Fail/Skip
6-6
Economizer Valve Test
Pass/Fail/Skip
6-7
Digital Unloader Valve Test
Pass/Fail/Skip
6-9
Liquid Injection Valve Test (If
Equipped)
Pass/Fail/Skip
6-10
Electronic Expansion Valve Test
Pass/Fail/Skip
7-0
High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped) Input
values that component opens
7-1
High Pressure Switch Open
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped) Input val-
ues that component closes
8-0
Perishable Mode Heat Test
Pass/Fail/Skip Result, STS, time it takes to heat to 16°C (60°F)
8-1
Perishable Mode Pulldown Test
Pass/Fail/Skip Result, STS, time it takes to pull down to 0°C
(32°F)
8-2
Perishable Mode Maintain Test
Pass/Fail/Skip Result, Averaged DataCORDER supply tem-
perature (SRS) over last recording interval.
9-0
Defrost Test
Pass/Fail/Skip Result, DTS reading at end of test, line voltage,
line frequency, time in defrost.
10-0
Frozen Mode Heat Test
Pass/Fail/Skip Result, STS, time unit is in heat.
10-1
Frozen Mode Pulldown Test
Pass/Fail/Skip Result, STS, time to pull down unit to -17.8°C
(0°F).
10-2
Frozen Mode Maintain Test
Pass/Fail/Skip Result, Averaged DataCORDER return tem-
perature (RRS) over last recording interval.
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......
Page 173: ......