4–61
T-365
Table 4–5 DataCORDER Function Code Assignments
NOTE:
Inapplicable Functions display “-----”
To Access: Press ALT.MODE key then CODE SELECT key
CODE NO.
TITLE
DESCRIPTION
dC1
Recorder Supply
Temperature
Current reading of the supply recorder sensor.
dC2
Recorder Return
Temperature
Current reading of the return recorder sensor.
dC3-5
USDA 1,2,3 Tem-
peratures
Current readings of the three USDA probes.
dC6-13
Network Data
Points 1-8
Current values of the network data points (as configured). Data point 1 (Code
6) is generally the humidity sensor and its value is obtained from the control-
ler once every minute.
dC14
Cargo Probe 4
Temperature
Current reading of the cargo probe #4.
dC15-19
Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24
Temperature Sen-
sors 1-5 Calibra-
tion
Current calibration offset values for each of the five probes: supply, return,
USDA #1, #2, and #3. These values are entered via the interrogation pro-
gram.
dC25
Future Expansion
This code is for future expansion, and is not in use at this time.
dC26,27
S/N, Left 4, Right 4 The DataCORDER serial number consists of eight characters. Function code
dC26 contains the first four characters. Function code dC27 contains the last
four characters. (This serial number is the same as the controller
serial number.)
dC28
Minimum Days Left An approximation of the number of logging days remaining until the Data-
CORDER starts to overwrite the existing data.
dC29
Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30
Date of Last Trip
start
The date when a Trip Start was initiated by the user. In addition, if the system
goes without power for seven continuous days or longer, a trip start will au-
tomatically be generated on the next AC power up. Press and hold “ENTER”
key for five seconds to initiate a “Trip Start.”
dC31
Battery Test Re-
sults
Shows the current status of the optional battery pack.
PASS:
Battery pack is fully charged.
FAIL:
Battery pack voltage is low.
dC32
Time: Hour, Minute Current time on the real time clock (RTC) in the DataCORDER.
dC33
Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34
Date: Year
Current year on the RTC in the DataCORDER.
dC35
Cargo Probe 4 Cal-
ibration
Current calibration value for the Cargo Probe. This value is an input via the
interrogation program.
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......
Page 173: ......