6.12 ELECTRONIC EXPANSION VALVE MALFUNCTION
Condition
Possible Cause
Remedy/Refer-
ence Section
Low suction pressure
Incorrect software and/or controller configuration
Check
Failed suction pressure transducer (SPT) or evaporator
pressure transducer (EPT)
Replace
Suction service valve partially closed
Open
Filter drier partially plugged
Low refrigerant charge
No evaporator air flow or restricted air flow
Excessive frost on evaporator coil
Evaporator fan(s) rotating backwards
EEV control malfunction
Failed digital unloader valve (DUV)
Replace
Loose or insufficiently clamped sensor
Replace
High suction pressure with low su-
perheat
Foreign material in valve
Failed suction pressure transducer (SPT) or evaporator
pressure transducer (EPT)
Replace
EEV control malfunction
Replace
Improperly seated powerhead
Ensure power-
head is locked
and in place
Liquid slugging in compressor
Failed suction pressure transducer (SPT) or evaporator
pressure transducer (EPT)
Replace
Failed EEV
Replace
6.13 AUTOTRANSFORMER MALFUNCTION
Condition
Possible Cause
Remedy/Refer-
ence Section
Unit will not start
Circuit breaker (CB
−
1 or CB
−
2) tripped
Check
Autotransformer defective
Power source not turned ON
Check
460 VAC power plug is not inserted into the receptacle
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......
Page 173: ......