Configurable Functions
- Cd50 through Cd53 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.
Cd50
CCPC Disabled
”OFF” = disabled.
”On” = enabled.
”SEtPt” = suspended by setpoint too low.
”CAHUM” = suspended by CA or humidity control.
”ACt” = suspended by ACT active.
”FAIL” = all return temperature probe failure for CCPC.
”PrtrP” = pretrip active.
”C LIM” = suspended by cool limit logic.
”PULL” = pulldown active.
“ALArM ” = suspended by shutdown alarm
Press enter, arrow keys, and then enter to select ”OFF” or ”On”.
If ”On” is selected, CCPC operation may be suspended as indicated
by one of the suspension codes listed above. If CCPC is not ”OFF” and
is not suspended, ”On” will be displayed.
Cd51
Automatic Cold Treatment
Parameter Selection
ACT-mode:
Cd51 increments of (1 day)_(1hr), Display: default “0_0 “
“done” mm-dd this will be display is ACT has completed
“ACt” value “On” “OFF” or “----“Display /Select: default “OFF“
“trEAt” value C / F on 0.1 degree increments Display/Select: default
“0.0C“
“DAyS” value “0 – 99” increments of 1 Display/Select: default “0“
“ProbE” value Probe positions ex ’1 2 _ 4’ ’1 _ 3 _’ Display: default “---- “
“SPnEW” value C / F on 0.1 increments Display/Select: default
“10.0C “
Initially Cd51 will display current countdown timer increments of (1
day)_(1hr), default“0_0
Pressing ENTER key will take the interface down into a hierarchy of
parameter selection menus (act, treat, days, probe and spnew setting).
Pressing ENTER key in any of the parameter selection menus com-
mits to selection of the currently displayed parameter and causes the
interface to descend into the next parameter selection menu. All
parameter selection menus alternate between a blank display and the
current selection in the right hand display.
Pressing CODE SELECT key in a selection menu cancels the current
selection activity and ascends back up to the next higher selection
menu (or to Cd51 display mode if that is the next higher).
If the operator does not press any key for five seconds the interface
reverts to normal system display and the current selection menu is
cancelled, but any previously committed changes are retained.
Available parameters and parameter ranges are a function of configu-
ration options and previously selected parameters as indicated
above.
Parameter with the exception of “Act” may not be altered if Cd51 is re-
entered if “Act” is “On”. When ACT has completed including reaching
the new setpoint “done” on the left display and the MONTH DAY of
completion on the right display will be displayed as the second entry
in the menu. Turning ACT off clears this entry. This action also resets
Cd51 to initial time remaining. ACT must then be turned on to view or
modify the additional parameters.
Whenever any auto Pre-trip test or Trip Start is initiated, ACT mode
goes to OFF.
Table 4–3 Controller Function Codes (Continued)
CODE #
TITLE
DESCRIPTION
Summary of Contents for 69NT40-561-300
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 22: ......
Page 34: ......
Page 108: ......
Page 116: ......
Page 164: ...T 365 8 2 Figure 8 2 Unit Wiring Diagram Based on Drawing 62ï11755 ...
Page 165: ...8 3 T 365 Figure 8 3 Wiring Diagram Based on Drawing 62ï11755 ...
Page 166: ...T 365 8 4 Figure 8 4 Wiring Diagram Based on Drawing 62ï11755 ...
Page 168: ......
Page 172: ......
Page 173: ......