DPM III xi series
Function Menu
04.18
Operating manual
49
7.7 I/O Parameters
Press key
to access the function menu.
Press key
as long as you arrive at the 'I/O Parameter' menu.
Press key
to select the menu.
IN signal level:
Indication of signal at which a print order is started.
+ = active signal level is 'high' (1)
− = active signal level is 'low' (0)
x = not activated signal level
s = status can be affected by interface
*
The modification of the signal level is only taken into consideration for
the operating modes I/O static, I/O dynamic, I/O static continuous and
I/O dynamic continuous.
Press key
to arrive at the next menu item.
OUT signal level:
Indication of signal level for output signal.
+ = active signal level is 'high) (1)
− = active signal level is 'low' (0)
s = Zustand kann über Schnittstelle beeinflusst werden*
Press key
to arrive at the next menu item.
Debounce:
Indication of debounce time of the dispenser input. The setting range
of the debounce time is between 0 and 100 ms.
In case the start signal is not clear then you can debounce the input
by means of this menu item.
Press key
to arrive at the next menu item.
Start signal delay:
Indication in time per second of the delay for the start signal.
Value range: 0.00 to 9.99.
Press key
to arrive at the next menu item.
IO protocol:
Indication of interface at which the modifications of input signals and
output signals (I/O) are sent.
Press key
to arrive at the next menu item.
Save signal
On:
The start signal for the next label can already be released during
printing the current label. The signal is registered from the printer. The
printer starts printing the next label immediately after finishing the
current one. Therefore time can be saved and performance be
increased.
Off:
The start signal for the next label can only be released if the
current label is printed to the end and the printer is again in 'waiting'
state (output 'ready' set). If the start signal was released already
before, so this is ignored.
*
in combination with Netstar PLUS
Summary of Contents for DPM III XI
Page 1: ......
Page 8: ......
Page 22: ...Technical Data DPM III xi series 22 Operating manual 04 18 Example 1 Example 2 Example 3 ...
Page 34: ......
Page 38: ......
Page 62: ......
Page 72: ...Signal Diagrams DPM III xi series 72 Operating manual 04 18 10 2 Mode 2 continuous mode ...
Page 84: ......
Page 90: ......
Page 92: ......
Page 95: ......
Page 96: ......