Error message
Cause
Remedy
116 Print position
The print position is not correct. Check TOP and RIGHT final
position switch for correct
function and position.
Check pneumatics for function
117 XML parameter
The parameters in the XML file
are not correct.
Please contact your
responsible distributor.
118 Invalid variable
Transferred variable is invalid
with customized entry.
Select correct variable without
customized entry and transfer
it.
119 No ribbon
During the print order the
ribbon roll becomes empty.
Defect at the transfer ribbon
photocell.
Change transfer ribbon.
Check transfer ribbon photocell
(service functions).
120 Wrong directory
Invalid target directory when
copying.
Target directory must not be
within the source directory.
Check target directory.
121 No label found
No label found at the rear
printhead (DuoPrint).
Soiled label photocell.
Labels not inserted correctly.
Insert new label roll.
Clean the label photocell.
Check if labels are inserted
correctly.
122 IP occupied
The IP address was already
assigned.
Assign a new IP address.
123 Print asynchronous
The label photocell does not
work in the order as it is
expected according to print
data.
Check label size and gap size.
The settings of the photocell
are not correct.
Check label photocell settings.
Settings of label size and gap
size are not correct.
Check correct loading of label
material.
No label found at the rear
printhead.
Insert new label roll.
Soiled label photocell.
Clean the label photocell.
Labels not inserted correctly.
Check if labels are inserted
correctly.
124 Speed too slow.
The print speed is too slow.
Increase the speed of
customers' machine.
125 DMA send buffer
Communication problem HMI.
Restart the printer.
126 UID conflict
Configuration RFID
programming faulty.
Run RFID initialising.
Summary of Contents for DPM III XI
Page 1: ......
Page 8: ......
Page 22: ...Technical Data DPM III xi series 22 Operating manual 04 18 Example 1 Example 2 Example 3 ...
Page 34: ......
Page 38: ......
Page 62: ......
Page 72: ...Signal Diagrams DPM III xi series 72 Operating manual 04 18 10 2 Mode 2 continuous mode ...
Page 84: ......
Page 90: ......
Page 92: ......
Page 95: ......
Page 96: ......