67
humiSteam -
cod. +030221910 rel. 5.2 - 07.11.2005
6 slow
E101
internal memory error
1. reset the default parameters
total
machine
reprog.
active
reprog.
flashes
(see Chap. 7.5)
shut-
disabled
by CAREL
by
CAREL
or 4 fast
2. if the problem persists, contact the CAREL down
flashes service
centre
red
LED
Not
E112
error in the parameters user
1. with the machine off check that there
-
machine
reprog.
active
reprog.
featured
are no defective electrical connections
disabled
params.
params.
or faults, then reprogram the parameters
2. reset the default parameters
(see Chap. 7.5)
3. if the problem persists, contact the CAREL
service centre
Not
E130
hour counter error
with the machine off check that there are
-
hour
reset
not
-
featured
no defective electrical connections or
counter
manual
active
faults, then reset the hour counter
saving
hour
(see par. 7.6)
disabled
counter
not
E120
room probe not connected
check the connection of the probe,
-
machine
manual
active
auto
featured
parameter A2 for the room probe and the
disabled
setting of parameter A0 (see chap. 7)
not
E123
outlet probe not connected
check the connection of the probe,
-
signal
manual
active
auto
featured
parameter A6 for the outlet probe and the
only
setting of parameter A0 (see chap. 7)
not
E132
cylinder being depleted signal
perform maintenance and/or replace the
-
signal
manual
not
auto
featured
cylinder
only
active
2 slow
E133
cylinder depleted signal
perform maintenance and/or replace the
signal
signal
not
not
-
flashes cylinder
only
only
available
active
red LED
9 slow
E134
cylinder full with machine off
with the machine off:
total
machine
manual
active
manual
flashes
signal
1. check for any leaks from the fill
shut-
disabled
red LED
electrovalve or the condensate return
down
pipe
2. check that the level sensors are clean
total shut-down
not
-
cleaning cylinder started signal
see paragraph 6.2.1
-
-
-
-
-
featured
not
E135
timeout signal (see parameter
perform maintenance and/or replace
-
signal
manual
active
after the
envisaged
“bb”) for maintenance
the cylinder
only
reset
manual
exceeded
hour reset
counter **
hour
counter
not
E136
reached final limit (1.5xbb)
replace the cylinder
-
disable
manual
active
after the
envisaged
of cylinder operating life
unit
reset
manual
hour
reset
counter **
hour
counter
not
-
complete draining of the
see paragraph 6.3.2.6
-
-
-
-
-
envisaged
cylinder activated
not
-
complete draining for
see paragraph 11.4.5
-
-
-
-
-
envisaged
extended inactivity
not
-
complete periodical
see paragraph 11.4.9
-
-
-
-
-
envisaged
draining active
not
-
anti-foam algorithm
see paragraph 11.4.3
-
-
-
-
-
envisaged
active
Tab. 10.3.1
* CAREL Humivisor (H or T)
** it is recommended to replace the cylinder first
Note:
for the P controllers the alarms cannot be reset. If the alarm is no longer active, it can only be reset by switching the machine off.
code displayed
controller
remote causes
solution
action
reset
alarm
reset
term.*
display (H)
relay
relay (H)
P
H
P
H