8400-M022-O1 Rev K
Model 190 Indicator
75
ERROR MESSAGES
Before You Call Service
The Cardinal 190 Weight Indicator has been designed to provide you with years of trouble-free
operation. However, should you experience a problem, please refer to the troubleshooting
guide below before you call for service. The following describes several types of symptoms
along with suggested remedies.
PROBLEM
POSSIBLE SOLUTIONS
The display does
not turn on
AC operation:
Is the AC power cord fully inserted into the wall receptacle?
Check the wall receptacle for proper AC power.
Try another electrical appliance in the same receptacle, does it work?
Check the circuit breaker.
Has there been a power failure?
Battery operation:
Check if the battery is installed correctly.
Is the battery discharged? Replace or recharge.
Incorrect weight
displayed
Has the indicator been calibrated?
Ensure that the scale platform isn't touching an adjacent object.
Check the load cell connector wiring.
If using four (4) wire load cells, ensure the sense lead jumpers (J4 & J5)
are installed.
Have proper operation procedures been followed?
The indicator will
not display weight
Refer to the Error Codes section and make certain that the "
oCAP
"
message is not displayed. If so, and the scale is not loaded, perform the
calibration procedure.
The printer prints
but does not use
the Print Tab
Settings or prints
a test ticket
The print tab setting or visual ticket format must be selected before
beginning the weighing operation or just before printing the ticket.
To select the ticket format before beginning the weighing operation:
1.
Press the
Fn/
key then the
key. The display will change
to the “
Prt=
”.
2.
Press the
TARE
key to show the current value.
3.
If the value displayed is acceptable, press the
TARE
key again
to save it.
4.
If the displayed value is incorrect (or another ticket format is
desired), use the
Fn/
key to toggle to a new setting and press
the
TARE
key to save it.
Allowable values for ticket formats are:
0 = print tab settings
1 = visual ticket format
NOTE:
When a print format is selected, it will remain active until
changed by the operator.