8400-M022-O1 Rev K
Model 190 Indicator
43
Options Setup
option
With
opt
displayed, press the
TARE
key. The display will change to show
opt=
.
Proceed to the
opt=
parameter.
opt?
With
opt?
displayed, press the
TARE
key. The display will change to
no
. Press the
Fn/
key to toggle to
yes
and press the
TARE
key. The display will change to
opt=
.
Proceed to the
opt=
parameter.
Otherwise, to skip the Options Setup, press the
TARE
key to advance to the
fUnC?
. prompt.
opt=
(Option)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to toggle to a new setting and press the
TARE
key to save
it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, Wi-Fi, or USB Option Card Installed
(See Appendix C, D, E and G for details)
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
(See Appendix F for details)
IMPORTANT!
The settings for the following prompts,
baUd=
,
Prty=
, and
Cont2=
are only applied when the
opt=
parameter is set to 0 or 1.
bAUd=
(Optional Serial Interface Baud Rate)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to toggle to a new baud rate setting for the serial ports and
press the
TARE
key to save it. Allowable settings are:
12 = 1200 Baud
24 = 2400 Baud
48 = 4800 Baud
96 = 9600 Baud
19 = 19.2k Baud
38 = 38.4k Baud
76 = 76.8k Baud