![Cardinal 190 Series Installation, Technical And Operation Manual Download Page 41](http://html.mh-extra.com/html/cardinal/190-series/190-series_installation-technical-and-operation-manual_2556155041.webp)
8400-M022-O1 Rev K
Model 190 Indicator
33
Serial Input/Output
Sio
With
sio
displayed, press the
TARE
key. The display will change to
baud=
. Proceed to
the
baud=
parameter.
Sio?
With
sio?
displayed, press the
TARE
key. The display will change to
no
. Press the
Fn/
key to toggle to
yes
and press the
TARE
key. The display will change to
baud=
. Proceed to the
baud=
parameter.
Otherwise, to skip Serial Input/Output setup, press the
TARE
key to advance to the
print?
. prompt.
bAUd=
(Serial Interface Baud Rate)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to toggle to a new baud rate setting for the serial ports and
press the
TARE
key to save it. Allowable settings are:
12 = 1200 Baud
24 = 2400 Baud
48 = 4800 Baud
96 = 9600 Baud
19 = 19200k Baud
38 = 38400 Baud
76 = 76800 Baud
Prty=
(Serial Interface Parity Setting)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to toggle to a new setting and press the
TARE
key to save
it. Allowable settings are:
0 = No Parity with 8 data bits
1 = Odd Parity with 7 data bits
2 = Even Parity with 7 data bits