8400-M022-O1 Rev K
Model 190 Indicator
73
About Scale Scroll Command
The wireless device sends:
<LF>B<CR>
The 190 will respond with the following (
NOTE:
The command must be repeated for each
response):
<LF>MFG:Cardinal Scale Mfg. Co.<CR>
<LF>MOD:190<CR>
<LF>REV:n.n.nn/1.1<CR>
<LF>END:<CR>
NOTE: n.n.nn
will be the version number for the 190 firmware.
Scale Information Command
The wireless device sends:
<LF>I<CR>
The 190 will respond with:
<LF>SMA:2/1.0<CR>
Scale Information Scroll Command
The wireless device sends:
<LF>N<CR>
The 190 will respond with the following:
<LF>TYP:S<CR>
<LF>CAP:uuu:ccc:n:d<CR>
<LF>CMD:TMCIN<CR>
<LF>END:<CR>
The
CAP
response will be repeated once for each unit of measure.
uuu
is the unit of measure.
ccc
the capacity for that unit of measure.
n
is the least significant count by digit (e.g., 1, 2, 5, 10, 20, ...).
d
is the decimal point position (0=none, 1=xxxxx.x, 2=xxxx.xx, 3=xxx.xxx).
NOTE:
the command must be repeated for each response.