8400-M022-O1 Rev K
Model 190 Indicator
39
Fine Span Adjustment
IMPORTANT! The
FSPAn
(
FSPAn?
) mode requires a load of 10% of Capacity
on the scale before adjustments can be made.
F span
Fine Span Adjustment (from
SETUP
Prompt)
1.
If Fine Span Adjustment is desired, with the
SETUP
prompt displayed, press the
UNITS/
key until the display shows the
FSPAn
prompt.
2.
Place a calibrated test weight on the scale and press the
TARE
key.
3.
The display will change to show the amount of the test weight, an
F
will be displayed to
the right of the annunciators and the annunciators will alternately flash off and on.
4.
Press the
Fn/
key to increase the span by 0.5 division
OR
press the
UNITS/
key to
decrease the span by 0.5 division.
5.
Press the
TARE
key to exit the Fine Span Adjustment and advance to the
Hires?
prompt.
Fspan?
Fine Span Adjustment (after pressing TARE
at last
prompt)
1.
With
fspan?
displayed, press the
TARE
key.
2.
The display will change to
no
.
3.
Place a calibrated test weight on the scale.
4.
Press the
Fn/
key to toggle to
yes
and press the
TARE
key.
5.
The display will change to show the amount of the test weight, an
F
will be displayed to
the right of the annunciators and the annunciators will alternately flash off and on.
6.
Press the
Fn/
key to increase the span by 0.5 division
OR
press the
UNITS/
key to
decrease the span by 0.5 division.
7.
Press the
TARE
key to exit the Fine Span Adjustment and advance to the
Hires?