background image

18

“PROG/OK” 

to return to

 ‘motions’

“PROG/OK” 

to confirm

Press the arrows 

to increase or 

decrease the value 

(max. 63)

* * * * * *  * * * * * * * *  *
*                            *

*   SET CONTRAST   *
*                  SEC.    *
*                            *

* * * * * *  * * * * * * * *  *

26

“PROG/OK” 

to return to

 ‘options’

OPTIONS

SAFETY DEVICES 

MOTION
DISPLAY
REMOTE

PROGRAM

TB FI
FS CP

TA TD

TC TAL

00.000.007
CC2X24    V1.00

OPTIONS

SAFETY DEVICES
MOTION
DISPLAY
REMOTE

Arrow

to scroll

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

OPTIONS
SAFETY DEVICES 

MOTION

DISPLAY
REMOTE

Arrow

to scroll

OPTIONS
SAFETY DEVICES 
MOTION

DISPLAY

REMOTE

Arrow

to scroll

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

SEQUENTIAL COM.

OPEN-SHUT/

OPEN-STOP-SHUT

AUTO. RECLOSING

ON/OFF

PRE-FLASHING

ON/OFF

PRE-FLASHING

ON/OFF

WARNING LIGHTS

FIXED/

INTERMITTENT

INDICATOR LIGHT 

FIXED/

INTERMITTENT

WARNING LIGHTS

FIXED/

INTERMITTENT

INDICATOR LIGHT

FIXED/

INTERMITTENT

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP 

INDICATOR LIGHT

FIXED/

INTERMITTENT

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP

TEST FI

ON/OFF

PHOTOCELL INVERT

DURING CLOSING/

AND IN STOP  

TEST FI

ON/OFF

TEST FS 

ON/OFF

TEST FS

ON/OFF

GATE DELAY

DURING OPENING

ON/OFF

ELECTRIC LOCK

ON/OFF

TEST FI

ON/OFF

TEST FS

ON/OFF

GATE DELAY 

DURING OPENING

ON/OFF

GATE DELAY

ON/OFF

ELECTRIC LOCK

ON/OFF

MEMO RADIO

ON/OFF

ELECTRIC LOCK

ON/OFF

REMOTE

ON/OFF

OUTPUT LC/CH2

RADIO CHANNEL/

COURTESY LIGHT

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

MEMO RADIO

ON/OFF

OUTPUT LC/CH2

COURTESY LIGHT/

RADIO CHANNEL

EXIT

“PROG/OK” 

to change

the value

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

                          

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

CONTACT TB

NC/8K2

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

“PROG/OK” 

to change

the value

CONTACT FI

NC/8K2

CONTACT FS

NC/8K2

CONTACT CP

NC/8K2

“PROG/OK” 

to change

the value

CONTACT FS

NC/8K2

CONTACT CP

NC/8K2

EXIT

“PROG/OK” 

to return to

 ‘safety devices’

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...5 

                          

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...4 

 

“PROG/OK” 

to confirm

“PROG/OK” 

to change

the value

MOTOR SELECTION

BL824

CURRENT SENSOR

LEVEL 1...5

LIMITED OPENING

SELECTION 1...4 

“PROG/OK” 

to change

the value

CURRENT SENSOR

LEVEL 1...5 

LIMITED OPENING

SETTING 1...5

DIST. FROM CLOSE

STEPS 1...9

 

 

“PROG/OK” 

to change

the value

“PROG/OK” 

to change

the value

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

                          

“PROG/OK” 

to confirm

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

                          

“PROG/OK” 

to change

the value

CONTRAST

0....63  

REAR LIGHTING

ALWAYS ON/60/30 SEC.

EXIT

“PROG/OK” 

to return to

‘display’

Note: 1

Note: 2

Note: 3

Note: 3

Note: 6

Note: 7

Note: 8

Note: 9

The number of 

manoeuvres 

carried out by 

the operator 

arm and the 

ECU model are 

always shown 

on the opening 

screen of the 

display.

The plug 

symbol

indicates that the 

ECU is working 

off mains power.

The fully

charged battery 

symbol

indicates that the 

ECU is working 

off battery power 

at 100%.

75%

50%

25%

0%

Note: 4

Note: 5

ITALIANO

FRANÇAIS

ENGLISH

NEDERLANDS

DEUTSCH

ESPAÑOL

PROGRAM

TB FI
FS CP

TA TD

TC TAL

00.000.007
CC2X24    V1.00

press both arrows 

simultaneously to enter

the language submenu

“PROG/OK” to confirm

Flashing on the display. You have to enter the programming mode to program the system. 

During normal operation it indicates that the "automatic repositioning" procedure is about to 

take place. In this case any commands received (

TA, TC, TAL or TD

) will automatically start 

this procedure.

This happens when an N.C. contact is activated (

FI, FS, CP

) during encoder programming or 

automatic repositioning. Once the passive state of the security devices has been reset the gate 

will start moving again automatically. It also happens if a blackout occurs during programming.

Safety device test error. Check the condition of the safety devices and make sure that the 

alarm cuts in when an obstacle interferes with the beam (indication white characters on a black 

background). In case of anomalies replace the damaged safety device or bridge the contact 

and deactivate the safety test  (option menu).

This occurs when the programmer sends a command to the motor and nothing happens (motor 

1/2

 doesn't move). Check the Faston connections of motor 

1/2

  and the condition of the fuses 

"

F3

", "

F4

" and then give another opening or closing command. If the motor still doesn't move 

you are faced with either a mechanical problem or a problem with the programmer. 

Encoder count error motor 

1/2

 . If this error occurs during normal motor operation it means 

that there is a problem with one of the encoder signals. Check the relative connections and 

carry out automatic repositioning.
Encoder direction error motor 

1/2

 : The gate movement direction is different from the encoder 

setting (eg. the gate moves in the closing direction while the program is carrying out the 

opening stage). Check motor 

1/2

  power supply connections.

Current sensor error motor 

1/2

 . When the gate is not moving this symbol means there is a 

problem with the current sensor 

1/2

 .

Opening this contact will provoke a travel direction inversion during the closing stage and 

during the opening stage.

If the sensor intervenes during the opening direction the gate inverts the travel direction immediately 

and proceeds to the fully open position. If the sensor intervenes during the closing direction the gate 

automatically inverts the travel direction of a few centimetres and then stops to free the obstacle.

   

Alarm indications

TB FI
FS CP

TA TD

TC TAL

PROGRAM

TB FI
FS CP

TA TD

TC TAL

OUT OF POS

TB FI
FS CP

TA TD

TC TAL

SAFETY ERROR

TB FI
FS CP

TA TD

TC TAL

STOP PROG

AUTO PROG

TB FI
FS CP

TA TD

TC TAL

ERROR MOT1/2

TB FI
FS CP

TA TD

TC TAL

ERROR ENC1/2

TB FI
FS CP

TA TD

TC TAL

ERROR DIR1/2

TB FI
FS CP

TA TD

TC TAL

ERROR SENS1/2

TB FI
FS CP

TA TD

TC TAL

ACT. SAFETY EDGE

TB FI
FS CP

TA TD

TC TAL

ACTIVE SENSOR

Press an arrow 

key to enter the 

main menu

LIMITED OPENING

SETTING 1...5

DIST. FROM CLOSE

STEPS 1...9 

GATE DELAY

STEPS 0...9

 

DIST. FROM CLOSE

STEPS 1...9 

GATE DELAY

STEPS 0...9 

BRAKING ROOM

SETTING 1...3

BRAKING ROOM

SETTING 1...3

BRAKING SPEED

SETTING 1...3

PAUSE TIME

130 SEC.

BRAKING SPEED

SETTING 1...3

PAUSE TIME

130 SEC.

EXIT

“PROG/OK” 

to confirm

Press the arrows to increase or 

decrease the value (max. 240 sec).

Keeping the arrows held down will 

force the value to scroll rapidly.

* * * * * *  * * * * * * * *  *
*                            *

*       

PAUSE TIME

      *

*                 

SEC.

     *

*                            *

* * * * * *  * * * * * * * *  *

180

GATE DELAY

STEPS 0...9 

BRAKING ROOM

SETTING 1...3

BRAKING SPEED

SETTING 1...3

“PROG/OK” 

to change

the value

Note: 10

“PROG/OK” 

to change

the value

Note: 11

“PROG/OK” 

to change

the value

Note: 12

Language choice:

•  Press the right and left buttons simultaneously to enter the language submenu.
•  Press the right and left buttons to change the language: Italian to English.
•  Press the "PROG/OK" button to confirm the choice.

Pause time programming or pause for 

automatic reclosing (if activated)

Automatic programming under way

Opening stage

Block during opening   

Closing stage

Block during closing 

 

Operational indications

TB FI
FS CP

TA TD

TC TAL

PAUSE

TB FI
FS CP

TA TD

TC TAL

AUTO PROG

TB FI
FS CP

TA TD

TC TAL

OPENING

TB FI
FS CP

TA TD

TC TAL

STOP OPENING

TB FI
FS CP

TA TD

TC TAL

CLOSING

TB FI
FS CP

TA TD

TC TAL

  STOP CLOSING

“PROG/OK” 

to confirm

PRESS the

transmitter

channel

to memorise

PRESS the

the same 

transmitter

channel

again

“PROG/OK” 

to confirm

Arrow

to scroll

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to confirm

OPTIONS

SAFETY DEVICES 

MOTION
DISPLAY

CALENDAR

REMOTE

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 1    *

*                           *

* * * * * *  * * * * * * * *  *

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 2    *

*                           *

* * * * * *  * * * * * * * *  *

MEMORISE

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*       CODE           *
*  

MEMORISED   

  *

* * * * * *  * * * * * * * *  *

“PROG/OK” 

to confirm

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 1    *

*                           *

* * * * * *  * * * * * * * *  *

PRESS the

transmitter

channel

to memorise

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*  ACTIVATION 2    *

*                           *

* * * * * *  * * * * * * * *  *

PRESS the

the same 

transmitter

channel

again

CANCEL

[Nr...]

* * * * * *  * * * * * * * *  *
*                           *

*       CODE           *
*   

CANCELLED 

   *

* * * * * *  * * * * * * * *  *

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to confirm

* * * * * *  * * * * * * * *  *

*       CANCEL         *

*  ALL MEMORY ?  *

* * * * * *  * * * * * * * *  *

PRESS ok to  

cancel all 

memory

or press exit

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY

CHANNEL FUNCTION

EXIT

Arrow

to exit

EXIT

OK

* * * * * *  * * * * * * * *  *
*   CANCELLING    *

* * * * * *  * * * * * * * *  *

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY

CHANNEL FUNCTION

EXIT

CHANNEL A

channel function A

CHANNEL

 

B

channel function B

CHANNEL C

channel function C

CHANNEL D

channel function D

EXIT

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to change

the value

ENCODING: S4XX  

MEMORISE

CANCEL

CLEAR ALL MEMORY
CHANNEL FUNCTION

EXIT

“PROG/OK” 

to toggle the 

value  between

S4XX & S500

“PROG/OK” 

to return to

the remote

menu

[AB--]

[AB--]

[AB--]

[AB--]

[AB--]

[AB--]

Note: 14

Note: 13

•  All the functions of the electronic programmer can be set in the Display menu "

LCD1

" using the three buttons contained therein:

-  use the arrows to navigate through the menu and/or to adjust the display contrast;

- use 

"PROG/OK"

 to modify the parameter settings and/or to confirm. 

  PROGRAMMING PROCEDURE (parameter setting)

Notes

:

1) 

The indicator light

 flashes slowly during opening, rapidly during closing; remains lit when the gate is blocked but not completely closed 

and is off when the gate is completely closed.

2) 

FI Mode:

FI

 also active when the gate is blocked: If the photocells are in alarm and the gate is blocked, no movement commands will be accepted 

(even opening commands);

FI

 active only during closing: In both cases activating the 

FI

 safety device during the closing stage will force travel direction inversion.

3) 

Photocell test (FI/FS) 

  If you enable the security test you will have to connect both the transmitter and the receiver to the controlled load output 

(

CTRL 24 Vdc

). When the test is enabled one second will pass between receiving a command and carrying it out.

4) 

Opening direction gate delay

  If you enable gate delay the following will occur: during the opening movement gate leaf 1 moves first and then gate leaf 2. In the closing 

direction gate leaf 2 moves first then gate leaf 1. If gate delay is disabled both gate leaves move simultaneously.

5) 

Electric lock

  If the electric lock is enabled the ELS output (binding post 8) will be activated before gate leaf 1 moves and will remain active until gate leaf 

1 has moved a few centimetres.

6) 

Select the type of motor

BL3924ERB  =   articulated (reversible)

BLi924 

=   inside operator 

HL2524ESB   =   underground motor (HL1824/2524)

BL824 

=   articulated 

BLi1000   =   inside operator 

BLTOW24  =   articulated  

BL224E 

=   straight arm

BL1924ASW  =   articulated

BL3924ESB   =   articulated  (self-locking)

BLEGOS  =   straight arm 

  

(BLEGOS/BLESOL)

Summary of Contents for 200/BL224E

Page 1: ...ento automatico Pagina 12 Comando via radio Pagina 12 Modalit di funzionamento Pagine 13 Funzionamento a batteria Pagina 13 Caratteristiche tecniche Pagina 48 ATENCI N Antes de iniciar la instalaci n...

Page 2: ...hoto lectrique ext rieure 5 Clignoteur 6 S lecteur cl 7 Serrure lectrique 8 Antenne C ble coaxial RG58 Imp dance 50 9 Interrupteur omnipolaire avec ouverture des contacts d au moins 3 mm 10 C ble d al...

Page 3: ...x 10 11 13 200 BL224E 2 SCHEMA DI MONTAGGIO ASSEMBLY MONTAGE MONTAGEGEARBEITEN ESQUEMA DE MONTAJE 200 BL224E All rights reserved Unauthorised copying or use of the information contained in this docume...

Page 4: ...Installation sind die grau markierten Zahlenwerte zu verwenden Importante Para una instalaci n perfecta utilizar los datos evidenciados en gris LIMITI D IMPIEGO LIMITS OF USE CONTRAINTES D UTILISATION...

Page 5: ...RIEURE R GLABLE HINTERER EINSTELLBARER HALTEB GEL SOPORTE POSTERIOR REGULABLE STAFFA ANTERIORE REGOLABILE FITTING THE ADJUSTABLE FRONT BRACKET PATTE ANT RIEURE R GLABLE VORNER EINSTELLBARER HALTEB GE...

Page 6: ...CTRL 24Vdc CMN LS LP CMN LC CH2 ELS 12Vdc CMN F4 10 A J3 F3 10 A BATTERY CHARGER J1 R1 J6 J2 J4 PROGRAM L2 00 000 007 CC2X24 V1 00 ANS400 TB FI FS CP TA TD TC TAL Enable Disable ANQ800 1 3 4 5 6 1 2 B...

Page 7: ...itore al momento dell acquisto di una nuova apparecchiatura di tipo equiva lente in ragione di uno a uno L adeguata raccolta differenziata per l avvio al riciclaggio al trattamento e allo smaltimento...

Page 8: ...3 Portare l attuatore nella normale posizione di funzionamento appoggiando al cancello la staffa di testa contrassegnandone poi la posizione Nota Posizionare l operatore perfettamente orizzontale veri...

Page 9: ...FI 3 FI S3 Segnalazione fotocellule di stop FS 3 FS S4 Segnalazione costa sensibile CP 3 CP S5 Segnalazione tasto di apertura TA TA S6 Segnalazione tasto di chiusura TC TC S7 Segnalazione comando seq...

Page 10: ...attuatore il modello della centralina e la versione del firmware rimane sempre visualiz zato sul display iniziale Il simbolo indica che la centralina alimentate dalla rete principale Il simbolo indic...

Page 11: ...INT COSTA TB FI FS CP TA TD TC TAL INT SENS PROG OK per confermare PREMERE sul trasmettitore il canale da memorizzare PREMERE sul trasmettitore lo stesso canale per memorizzare PROG OK per confermare...

Page 12: ...oce CANCEL TOTALE Memorizzazione di ulteriori canali via radio solo S449 S486 La memorizzazione pu essere anche attivata via radio senza aprire la scatola dove alloggiata la centralina se l impo stazi...

Page 13: ...o essere spostate a mano una volta ribloc cati il programmatore provveder al ripristino della posizione dopo due tentativi consecutivi di arrivare in battuta 4 Manovra di emergenza Lamanovradiemergenz...

Page 14: ...ione della porta e quindi al ripristino dell alimentazione di rete si dovr eseguire la procedura di riposizionamento vedi pag 8 Evitare di lasciare il programmatore disalimentato per periodi prolungat...

Page 15: ...obligedtoeithertaketheproducttoasuitabledifferentialcollectionsitefor electronicandelectricalgoodsortosenditbacktothemanufacturerifthe intentionistoreplaceitwithanewequivalentversionofthesameproduct...

Page 16: ...ction travel distance and rotate the mechanical travel rings 7 and 9 along the screw to their optimum position Fix the arm to the rear mooring bracket 3 using the retaining pin 1 fig 2 page 3 Move the...

Page 17: ...e inverting photoelectric cells FI 3 FI S3 Indicator for the stop photoelectric cells FS 3 FS S4 Indicator for the safety edge CP 3 CP S5 Indicator for the opening button TA TA S6 Indicator for the cl...

Page 18: ...ONTRAST 0 63 REAR LIGHTING ALWAYS ON 60 30 SEC EXIT PROG OK to return to display Note 1 Note 2 Note 3 Note 3 Note 6 Note 7 Note 8 Note 9 The number of manoeuvres carried out by the operator arm and th...

Page 19: ...n to English Press the PROG OK button to confirm the choice Pause time programming or pause for automatic reclosing if activated Automatic programming under way Opening stage Block during opening Clos...

Page 20: ...erior channels via radio S4XX transmitters The system can be remotely activated using radio control devices with outopeningthereceiver bysetting MEMORADIO hasbeenactivated in the OPTIONS menu 1 Using...

Page 21: ...EMORIZZAZIONE CODICE TX TX TXQ504C4 29 10 2013 DM0912 Description Product Code Date Drawing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 0438 401818 Fax...

Page 22: ...tely flat during blackouts the pro grammer will lose the position of the door and therefore when power returns after the first command given you will have to carry out the repositioning procedure see...

Page 23: ...ve Parcons quent l utilisateurdoitremettrel appareil uncentredecollectes lectivedesd chets lectroniqueset lectriques ouaurevendeurquiesttenu lorsqu ilfournitunnouvelappareil defaire ensortequelesd che...

Page 24: ...cer les but es m caniques 7 et 9 fig 2 situ es sur la vis en les faisant tourner dans une position optimale Assembler l op rateur la patte post rieure 3 au moyen de l axe 1 fig 2 page 3 Placer l op ra...

Page 25: ...CMN commun pour toutes les entr es sorties 12 LPsortieclignoteur24Vdc25Wactivationintermittente 50 12 5Wactivation continue 13 LS sortie lampe t moin 24 Vdc 3 W 14 CMN commun pour toutes les entr es...

Page 26: ...3 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour confirmer CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 30 SEC SORTIE PROG OK pour changer le valeur CONTRASTE 0 63 LUMIERE FONDE TOUJOUR ON 60 30...

Page 27: ...TD TC TAL INT SENSEUR ITALIANO FRAN AIS ENGLISH NEDERLANDS DEUTSCH ESPA OL PROGRAM TB FI FS CP TA TD TC TAL 00 000 007 CC2X24 V1 00 appuyer simultan ment sur les deux fl ches pour acc der au sous men...

Page 28: ...min l effacement total de la m moire l afficheur revient la rubrique EFF TOTAL M morisation par radio d autres canaux seulement S4XX Cette m morisation peut galement tre activ e via radio sans devoir...

Page 29: ...yon d action de la t l commande et qui ont au moins un canal de l metteur de m moris enclencheront simultan ment l avertisseur sonore B1 fig 1 2 Pour s lectionner le r cepteur dans lequel il faut m mo...

Page 30: ...n cas de coupure de courant le programmateur perd la m morisation de la position du portail Par cons quent d s r tablissement du r seau d ali mentation il faudra lancer le proc d de repositionnement v...

Page 31: ...nszyklus getrennt von anderen Abf llen gesammelt werden muss Der Benutzer muss daher das Ger tingeeigneteZentrenf rdiegetrennteSammlungvonElektronik undElek troschrottbringenoderzumZeitpunktdesErwerbs...

Page 32: ...n Anschl ge 7 und 9 Abb 2 durch Drehung auf der Schraube in die optimale Position bringen Mitdemdaf rvorgesehenenBolzen 1 denAntriebamhinterenHalteb gelbefestigen 3 Abb 2 S 3 Den Antrieb in die normal...

Page 33: ...S1 Anzeige f r Blockiertaste TB 3 TB S2 Anzeige Bewegungsumkehrunglichtschranken FI 3 FI S3 Anzeige Lichtschranke f r Stop FS 3 FS S4 Anzeige Sicherheitsleiste CP 3 CP S5 Anzeige ffnungstaste TA TA S...

Page 34: ...an dass das Steuerger t von der zu 100 g e l a d e n e n Batterie gespeist wird 75 50 25 0 Anmerkung 1 PROG OK R ckkehr zum Men Bewegung Pfeil klicken um zu verschieben Anmerkung 2 Anmerkung 3 Anmerk...

Page 35: ...Italienisch Deutsch Zur Best tigung der Sprache die Taste PROG OK dr cken PROG OK um zu best tigen Die zu speichernde Kanaltaste auf dem Sender dr cken Die zu speichernde Kanaltaste auf dem Sender dr...

Page 36: ...peicherung weiterer Kan le ber Funk nur S4XX Die Speicherung kann auch ber Funk aktiviert werden ohne die Dose zu ffnen in der sich das Steuerger t befindet wenn die Einstellung FUNKSPEICHERUNG im Men...

Page 37: ...wing number P J Heath CARDIN ELETTRONICA S p A 31020 San Vendemiano TV Italy via Raffaello 36 Tel 0438 401818 Fax 0438 401831 Draft All rights reserved Unauthorised copying or use of the information c...

Page 38: ...m versorgen angeschlossenen Stromabnehmer Wenn sich die Batterie vollst ndig entleert bei fehlender Netzspannung verliert die Steuerung die Position des Tors und daher ist bei der Wiederherstellung de...

Page 39: ...minada su vida til debe ser recogidoporseparadodelosdem sresiduos Porlotanto elusuariodeber entregar el equipo en los centros de recogida selectiva especializados en residuos electr nicos y el ctricos...

Page 40: ...se controla electr nicamente con inicio lento e incremento posterior la velocidad se reduce con adelanto respecto a la llegada al tope de manera de obtener una parada controlada La programaci n realiz...

Page 41: ...ersi n FI 3 FI S3 Se alizaci n fotoc lulas de parada FS 3 FS S4 Se alizaci n banda sensibile CP 3 CP S5 Se alizaci n tecla de apertura TA TA S6 Se alizaci n tecla de cierre TC TC S7 Se alizaci n contr...

Page 42: ...30 SEG SALIDA PROG OK para regresar al men pantalla El n mero de las maniobras del operador el modelo de la centralita y la versi n del firmware queda siempre visualizado en la pantalla inicial del di...

Page 43: ...funcionamiento TB FI FS CP TA TD TC TAL PAUSA TB FI FS CP TA TD TC TAL AUTO PROG TB FI FS CP TA TD TC TAL APERTURA TB FI FS CP TA TD TC TAL STOP APERTURA TB FI FS CP TA TD TC TAL CIERRE TB FI FS CP T...

Page 44: ...Lamemorizaci npuedeactivarsetambi nv aradio sinabrirlacajadondela centralita est alojada si la configuraci n MEMO RADIO ha sido activada en el men OPCIONES 1 Utilizando un radiomando en el cual al me...

Page 45: ...o activaruna delasteclasdecanaldelmismoemisor Losreceptoresquenocontenganel c digodedichateclasedesactivar nconlaemisi ndeun bip de5segundos deduraci n encambio elquecontengaelc digoemitir otro bip qu...

Page 46: ...do falta la corriente el programador pierde la posici n de la cancilla y cuando se restablece la alimentaci n de red se deber repetir el procedimiento de reposicionamiento ver p g 40 Evitar que el pro...

Page 47: ...erie BL Tipo di apparato Automazione a 24 Vdc per cancelli a battente con centralina esterna Modello BL224 BL224E BL224ESB centrale di comando CC242ETOP CC242ETOPCB CC242EXTOPCB Marchio Cardin Elettro...

Page 48: ...ations Power supply Vac 230 Frequency Hz 50 60 Current input A 1 2 Maximum power yield W 250 Temperature range C 20 55 Power output for 1 or 2 motors W 60 60 Class II device Cls Incorporated receiver...

Reviews: