15
It is the responsibility of the installer to make sure that the following
public safety conditions are satis
fi
ed:
1) Ensure that the gate operating installation is far enough away
from the main road to eliminate possible traf
fi
c disruptions.
2) The operator must be installed on the inside of the property and
not on the public side of the gate. The gates must not swing
outwards onto a public area.
3) The gate operator is designed for use on gates through which
vehicles are passing. Pedestrians should use a separate
entrance.
4) The gate must be in full view when it is operating therefore
controls must be situated in a position where the operator can
see the gate at all times.
5) At least two warning signs (similar to the example on the right)
should be placed, where they can be easily seen by the public,
in the area of the system of automatic opera-
tion. One inside the property and one on the
public side of the installation.
These signs must be indelible and not hidden
by any objects (such as tree branches, deco-
rative fencing etc.).
6) Make sure that the end-user is aware that
children and/or pets must not be allowed to
play within the area of a gate installation. If
possible include this in the warning signs.
7) Whenever a fully open gate leaf comes close to a
fi
xed structure
(400 mm) the space must be protected by an anticrush buffer
(
fi
g. 1, detail 11).
8) If you have any questions about the safety of the gate operat-
ing system, do not install the operator. Contact your dealer for
assistance.
WARNINGS FOR THE USER
Before carrying out any cleaning or maintenance operations make
sure the power is disconnected at the mains.
The minimum controls which may be installed are OPEN-STOP-
CLOSE, these controls must be installed in a location not acces-
sible to children. During the opening/closing manoeuvre check
for correct operation and activate the emergency stop button in
case of danger.
During blackouts the gate can be released and manually
manoeuvred using the supplied release key (see manual release
pag.17).
Periodically check the moving parts for wear and tear and grease
if required, paying particular attention to the never ending screw
pos.11 fig.3 (200/BL202C), using lubricants which maintain their
friction levels unaltered throughout time and are suitable for tem-
peratures of -20 to +70°C.
In case of failure or operational anomalies switch off the power at
the mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices
(photoelectric cells etc.).
Eventual repair work must be carried out by specialised personnel
using original spare parts.
The appliance is not suitable for continuous operation and must
be adjusted according to the model (see technical data on page
28).
IMPORTANT REMARKS IMPORTANT REMARKS IMPORTANT REMARKS
IMPORTANT SAFETY INSTRUCTIONS
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING
• These instructions are aimed at professionally quali
fi
ed "INSTALL-
ERS OF ELECTRICAL EQUIPMENT" and must respect the local
standards and regulations in force.
All materials used must be approved and must suit the environ-
ment in which the installation is situated.
• This appliance must be used exclusively for the purpose for
which it has been made:
"i.e. for the automation of gates and doors".
Any non authorised modi
fi
cations are to be considered improper
and therefore dangerous. The manufacturer accepts no liability
for situations arising from the use of an electrical installation
which does not conform to the local standards and regulations in
force and in particular when the earthing circuit is not ef
fi
cient.
USE
The appliance may be used to operate hinged gates, with one or
two gate leaves. The appliances may be fitted both to the right
and to the left of the passageway.
This manual covers the following models:
200/BL202Self-locking electromechanical operator suitable for
hinged gates up to 2,0 metres in length and 150 Kg in weight
(per gate leaf).
200/BL202L Self-locking electromechanical operator suitable for
hinged gates up to 2,0 metres in length and 150 Kg in weight (per
gate leaf).
If used with the maximum travel distance an opening angle of 90°
and the addition of an electric locking device, it can be used for
gates up to 4,0 metres in length and 150 Kg in weight.
200/BL202C Self-locking electromechanical operator suitable for
hinged gates up to 1,80 metres in length and 150 Kg in weight
(per gate leaf).
If used with the maximum travel distance an opening angle of 90°
and the addition of an electric locking device, it can be used for
gates up to 3,0 metres in length and 150 Kg in weight.
200/BL352 Reversible electromechanical operator suitable for
hinged gates up to 3,5m in length and 300 Kg in weight (per gate
leaf).
200/BL452 Reversible electromechanical operator suitable for
hinged gates up to 4,5m in length and 300 Kg in weight (per gate
leaf).
TECHNICAL DESCRIPTION
- Single phase motor with incorporated overload protector housed
in a cast aluminium case.
- External carter in extruded aluminium.
- Release mechanism components in shockproof plastic.
- Geared motor with steel gears enclosed in a die cast two-piece
aluminium shell (BL202-202L-202C).
- Silent running epicycloid reduction motor with a never ending
universal ball screw in steel (BL352-452).
- Brackets and accessories in zinc-plated steel.
- Lubrication using permanently
fl
uid grease.
ACCESSORIES
206/BL201STAP
- Adjustable rear bracket for
fi
tting to a
wall
206/BL201SUAR - Adjustable rear plate for
fi
tting to a gate
980/XLSE11C
- Electric locking device 12Vac
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION
TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
. NOT READING THESE IMPORTANT
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
USER INSTRUCTIONS