COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
2-47
CHAPTER 2 USING THE MACHINE
3.6 Numeric Parameter Setting (#3 NUMERIC Param.)
No.
0 2
0 3
0 4
0 5
0 6
0 9
1 0
1 1
1 3
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 4
2 5
2 7
2 8
Item
RTN transmission condition (1)
RTN transmission condition (2)
RTN transmission condition (3)
NCC pause length (pre-ID code)
NCC pause length (post-ID code)
number of digits of telephone numbers in
comparison between transmitting and re-
ceiving machine
line connection identification time length
T.30 T1 timer (for reception)
T30.EOL timer
hooking detection time length
time to tentative response at time of fax/tel
switch-over
pseudo RBT signal pattern ON length
pseudo RBT signal pattern OFF time
length (short)
pseudo RBT signal pattern OFF time
length (long)
pseudo CI signal pattern ON time length
pseudo CI signal pattern OFF time length
(short)
pseudo CI signal pattern OFF time length
(long)
fax/tel switch-over pseudo RBT transmis-
sion level
answer telephone CNG motor time length
V.21 low-speed flag preamble detection
time length
menu selection screen display time length
Range of settings
1 to 99%
2 to 99 times
1 to 99 lines
0 to 60 sec
0 to 60 sec
0 to 20 digits
0 to 9999 (10ms)
0 to 9999 (10ms)
500 to 3000 (10ms)
0 to 999 (10ms)
0 to 9 sec
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 999 (10ms)
0 to 20 dBm
0 to 999 sec
1 to 99 (10ms)
1 to 60 sec
Initial setting
1 0
1 5
1 2
4
4
6
5500
3500
1300
1 2 0
4
1 0 0
0
2 0 0
1 0 0
0
2 0 0
2 0
6 0
3
3