COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
7-11
CHAPTER 7 TROUBLESHOOTING
2) Loosen the screw [3], and move the slide guide to the front/rear with reference to the in-
dex graduated at 1-mm intervals until the registration is as indicated.
[3]
F07-103-05
Memo
A shift of the slide guide up by 1 mm will increase the registration on the
right (top of paper) by 1 mm.
Do not remove the screw [3]; otherwise, you must work as instructed for
mounting of the slide guide. (See 2.8.1.5 of Chapter 5)