[No. 02. 03, 04]
Use it to set conditions for RTN signal transmission. If an error occurs often when the RTN
signal is transmitted at time of reception, increase the parameters to loosen the RTN signal
transmission conditions.
Memo
The following error codes are associated with the transmission of the RTN
signal at time of reception:
##104, ##107, ##114, ##201
The RTN signal transmission condition (1) is the ratio of the number of error
lines in relation to the total number of lines per page of reception images.
The RTN signal transmission condition (2) is the reference value
*2
for burst
errors
*1
.
The RTN signal transmission condition (3) is the number of errors not reach-
ing the reference value for burst errors.
*1: transmission errors spanning several lines.
*2: If set to ‘15’, a transmission error spanning 5 consecutive lines is
identified as a burst error.
If any of these conditions is detected while an image signal is being revised,
the RTN signal will be transmitted after receiving the procedure signal from
the transmitting machine. A higher parameter will make the transmission of
the RTN signal more difficult.
[No. 05]
Use it to set the length of item (pause) automatically put between the access code an the ID
code when a number is dialed on an NCC (new common carrier) line.
[No. 06]
Use it to set the length of time (pause) automatically put between the ID code and the tele-
phone number of the other party when a number is dialed on an NCC (new common carrier)
line.
[No. 09]
Use it to set the number of TSI comparison digits (last XX digits) for a telephone number
cross check.
[No. 10]
Use it to set the length of time for line connection identification. If an error occurs often be-
cause of the line condition at time of a communication, increase the parameter.