COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
5 - 9
CHAPTER 5 MECHANICAL SYSTEM
3) Close the cartridge cover.
4) Disconnect the connector [3], and de-
tach the control panel [2].
To prevent damage to the
flexible cable, be sure to lift
the control panel slightly as
shown when disconnecting
the connector [3].
Memo
To mount the control panel,
turn it over as shown in
F05-201-14, and connect
the connector [4]; then, turn
back over [5] the control
panel to facilitate the work.
[3]
[2]
F05-201-13
[5]
[4]