COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
CHAPTER 5 MECHANICAL SYSTEM
5-60
2.8.2.4 Removing the Original Separation Pad
1) Open the ADF.
2) Hold the tab, and detach the white
plate[2].
[1]
[2]
F05-208-18
3) Remove the spring [3], and detach the
original separation pad [4].
[4]
[3]
F05-208-19