COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
CHAPTER 7 TROUBLESHOOTING
7-28
3.1.11 The output has white spots (horizontal).
3.1.12 The output has white lines (horizontal).
Static eliminator
1) Is the static eliminator soiled?
YES: Clean it.
Back of copyboard glass (back of shading plate; dirt)
2) Try cleaning the back of the shading plate of the copyboard glass.
Is the problem corrected?
YES: End.
Shading position
3) Change the setting of No. 19 under ‘#6 SCANNER’ in service mode.
Is the problem corrected?
YES: End.
Transfer charging roller
4) Is the transfer charging roller soiled?
YES: Clean it. If the problem is not corrected, replace it.
Cartridge, Fixing assembly
5) Try replacing the cartridge. Is the problem corrected?
YES: End.
NO:
Replace the fixing assembly.