background image

 
 
 
 
 
 

LV-7565 

 

EXPAND SERIAL FUNCTIONAL 

SPECIFICATION

 

 
 
 
 
 
 
 

History of Modification

 

 

Rev. 

Date 

Page 

Contents

 

 2004. 

10.19  

New Document

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LV-7565

Page 1: ...LV 7565 EXPAND SERIAL FUNCTIONAL SPECIFICATION History of Modification Rev Date Page Contents 2004 10 19 New Document...

Page 2: ...us Read Command Table 11 6 3 Video Status Read Command Table 11 6 4 Input Status Read Command Table 11 6 5 Screen Status Read Command Table 12 6 6 Lamp Status Read Command Table 12 6 7 Sound Status Re...

Page 3: ...8 6 2 CF_SOURCE Command 22 8 6 3 CF_INPUT1 Command 22 8 6 4 CF_INPUT2 Command 22 8 6 5 CF_INPUT3 Command 23 8 6 6 CF_INPUT4 Command 23 8 6 7 CF_SYSTEM Command 23 8 7 Screen Control Command 24 8 7 1 C...

Page 4: ...mage Series Status Read Command 32 9 4 1 CR_BRIGHT Command 32 9 4 2 CR_CONT Command 32 9 4 3 CR_COLOR Command 32 9 4 4 CR_TINT Command 33 9 4 5 CR_SHARP Command 33 9 4 6 CR_GAMMA Command 33 9 4 7 CR_W...

Page 5: ...9 8 5 CR_VSCALE Command 40 9 8 6 CR_VPOS Command 41 9 8 7 CR_HSCALE Command 41 9 8 8 CR_HPOS Command 41 9 9 Lamp Series Status Read Command 41 9 9 1 CR_LAMPREPL Command 41 9 9 2 CR_LAMPMODE Command 4...

Page 6: ...Expand Serial Command Specification Page 5 of 46 9 12 3 CR_FREEZE Command 45 9 12 4 CR_PTIMER Command 45 9 12 5 CR_INFPFAIL Command 45 9 12 6 CR_TEMPWARN Command 46 9 12 7 CR_TEMPFAIL Command 46...

Page 7: ...al commands 2 Serial Interface Specification 2 1 Communication Specification Item Specification Synchro system Asynchronou Transmission Speed 9600 19200 Date Length 8 bit Parity None Stop Bit 1 Flow C...

Page 8: ...r Until the projector receives the carriage return since the projector has received the first data 3 5 A projector sends a return command in a few ms to 8000ms after the projector has received the com...

Page 9: ...stment 3 5 2 It takes about 8 seconds for internal initialization after plugging in AC power During this time it cannot process Command Do not issue any commands 4 Name Definition 4 1 Data from a cont...

Page 10: ...setting status CF_COLMNLD_ 1 CR Call color management setting status CF_TURBO_ 1 CR Control Turbo Bright 5 2 PC Control Command Table Execute command Item CF_FSYNC_ 1 CR Set Fine Sync value CF_TDOTS_...

Page 11: ...CF_LAMPH_ 1 CR Reset Lamp total running time CF_LAMPMODE_ 1 CR Select Lamp mode 5 6 Sound Series Command Table Execute command Item CF_VOLUME_ 1 CR Set Volume value CF_MUTE_ 1 CR Set Sound mute On Of...

Page 12: ...t setting 6 2 PC Status Read Command Table Status read command Item CR_FSYNC CR Read Fine Sync value CR_TDOTS CR Read Total Dots value CR_CLAMP CR Read Clamo value CR_H POS CR Read Horizontal Position...

Page 13: ...Read Sound mute setting CR_BLTINSP CR Read Built in Speaker setting 6 8 Setting Status Read Command Table Status read command Item CR_BBACK CR Read Blue Back setting CR_DISP CR Read Display setting C...

Page 14: ...coded a received data and ready to receive the next command it will return acknowledgment 000 CR 0x06 0x0D When received Function Execute Command nnn CR 000 unable to execute any value except for 000...

Page 15: ...ode CR 8 4 2 CF_CONT Command Command CF_CONT_ 1 CR 1 000 063 Directly select the Contrast setting value UP Contrast setting value 1 DN Contrast setting value 1 Details Set the User control Contrast va...

Page 16: ...lue 1 DN Sharpness setting value 1 Details Set the User control Sharpness value The value set by their Command will not be saved to the Projector Therefore when All Off the Projector the value will re...

Page 17: ...l return to the original setting For Stand by mode this value stays Only valid when it is in the usual Power On state Acceptable 000 CR Response Unacceptable Error Code CR 8 4 9 CF_NZRED Command Comma...

Page 18: ...stment to Custom Details Reset and Store for Image adjustment When it is in usual Power On state this is valid STR1 is the same as Custom when choosing Store on OSD menu The setting value set in Custo...

Page 19: ...mand will not be saved to the Projector Therefore when All Off the Projector the value will return to the original setting Stand by mode stays Note When 1 is directly specified this command is not eno...

Page 20: ...when it is in the usual Power On state The value set by this Command will not be saved to the Projector Therefore when All Off the Projector the value will return to the original setting Stand by mod...

Page 21: ...ng value 1 DN Display Line setting value 1 Details Set Display Line Only valid when it is in the usual Power On state The value set by this Command will not be saved to the Projector Therefore when Al...

Page 22: ...st status to MODE 5 Details Store current PC Adjust status each parameter status such as Total dots to Mode1 5 This command operates the same operation as storing to Mode1 Mode5 in PC Adjust Menu Only...

Page 23: ...fied 1 the response will be 101 and the Command is not be executed Acceptable 000 CR Response Unacceptable CR 8 6 3 CF_INPUT1 Command Command CF_INPUT1_ 1 CR 1 DIGITAL Select DVI Input ANALOG Select A...

Page 24: ...6 7 CF_SYSTEM Command Command CF_SYSTEM_ 1 CR Input is PC MODE1 Select Mode 1 MODE2 Select Mode 2 MODE3 Select Mode 3 MODE4 Select Mode 4 MODE5 Select Mode 5 1 Input is Video AUTO Select system Auto...

Page 25: ...REN_ 1 CR 1 ON Select Full Screen OFF Cancel Full Screen Input is Computer Set Cancel Full Screen Only valid when it is in the usual Power On state The value set by this Command will not be saved to t...

Page 26: ...edge shorter with a large range RST Keystone off Details Change Keystone range Only valid when it is in the usual Power On state When the range is over the maximum a Projector accepts the Command but...

Page 27: ...4 14 15 15 Details Set V Position Only valid when it is in the usual Power On state Acceptable 000 CR Response Unacceptable Error Code CR 8 7 10 CF_HSCALE Command Command CF_HSCALE_ 1 CR 1 The same as...

Page 28: ...eptable Error Code CR 8 9 Sound Series Command 8 9 1 CF_VOLUME Command Command CF_VOLUME_ 1 CR 1 000 063 Directly set Volume value UP Volume setting value 1 DN Volume setting value 1 Details Control V...

Page 29: ...n EEEPROM When All Off the Projector the setting will valid Acceptable 000 CR Response Unacceptable Error Code CR 8 10 2 CF_DISP Command Command CF_DISP_ 1 CR 1 ON Select Display OFF Cancel Display De...

Page 30: ...cceptable Error Code CR 8 10 6 CF_RCODE Command Command CF_RCODE_ 1 CR 1 001 Select Code1 002 Select Code2 Details Select Remote Control Code Only valid when it is in the usual Power On state The valu...

Page 31: ...tored in EEEPROM When All Off the Projector the setting will valid Acceptable 000 CR Response Unacceptable Error Code CR 8 10 10 CF_P MANETIME Command Command CF_P MANETIME_ 1 CR 1 01 30 Directly set...

Page 32: ...KEY Bar the use of KEY Details Set bar the use of RC KEY Only valid when it is in the usual Power On state Acceptable 000 CR Response Unacceptable Error Code CR 8 10 13 CF_FDEFAULT Command Command CF_...

Page 33: ...Dots of Projector by expand Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR 9 3 Operation Requirement Should be always operated 9 4 Image Series Status Read Command 9 4 1 CR_BRIGHT Command Command CR_BRI...

Page 34: ...MMA Command Command CR_GAMMA CR Details Read Gamma value of user control Acceptable 000_ 1 CR 1 000 015 Response Unacceptable CR 9 4 7 CR_WBAL R Command Command CR_WBAL R CR Details Read White Balance...

Page 35: ...Command Command CR_PROGV CR Details Read Progressive setting status Acceptable 000_ 1 CR 1 L1 Progressive Mode L1 setting L2 Progressive Mode L2settiing OFF Progressive cancellation Response Unaccepta...

Page 36: ...SW Off Response Unacceptable 000_ 1 CR 9 5 PC Series Status Read Command 9 5 1 CR_FSYNC Command Command CR_FSYNC CR Details Read Fine Sync value Acceptable 000_ 1 CR 1 0000 0031 Response Unacceptable...

Page 37: ...clear Command 9 5 6 CR_DDOTS Command Command CR_DDOTS CR Details Read Display Dots value Acceptable 000_ 1 CR 1 0000 nnnn nnnn Total Dots Horizontal Position Response Unacceptable Error Code CR Invali...

Page 38: ...ADJ CR Details Read PC signal for current system Acceptable 000_ 1 CR 1 XGA1 HDTV1080 MODE1 EXT6 Etc Response Unacceptable CR 9 6 Video Series Status Read Command 9 6 1 CR_SERSYS Command Command CR_SE...

Page 39: ...O Video input is selected S VIDEO S Video input is selected YPBPR Y Pb Pr input is selected Response Unacceptable Error Code CR Invalid CR When receives unclear Command 9 7 3 CR_SRCINP1 Command Comman...

Page 40: ...work Viewer mode status Response Unacceptable CR 9 7 7 CR_SYSTEM Command Command CR_SYSTEM CR Details Read selected System Acceptable 000_ 1 CR When Input is PC series MODE1 MODE2 MODE3 MODE4 MODE5 1...

Page 41: ...nal to 16 9 WIDE Selected 16 9 screen non 4 3 signal Response Unacceptable Error Code CR Invalid CR When receives unclear Command 9 8 3 CR_ KYSTNMODE Command Command CR_KYSTNMODE CR Details Read Keyst...

Page 42: ...CR Details Read H Position setting status Acceptable 000_ 1 CR 1 64 064 Response Unacceptable CR 9 9 Lamp Series Status Read Command 9 9 1 CR_LAMPREPL Command Command CR_LAMPREPL CR Details Read Lamp...

Page 43: ...CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Read Sound Mute setting status Acceptable 000_ 1 CR 1 ON Sound Mute On OFF Sound Mute Off Response Unacceptable CR 9 10 3 CR_BLTINSP Command Comman...

Page 44: ..._RCODE Command Command CR_RCODE CR Details Read Remote Control Code setting status Acceptable 000_ 1 CR 1 001 Selected Code1 002 Selected Code2 Response Unacceptable CR 9 11 5 CR_LANG Command Command...

Page 45: ...OWN Power Management is Shut Down mode Response Unacceptable CR 9 11 8 CR_P MANETIME Command Command CR_P MANETIME CR Details Read the time to start Power Management Acceptable 000_ 1 CR 1 001 030 1 m...

Page 46: ...and Command CR_FREEZE CR Details Read Freeze setting status Acceptable 000_ 1 CR 1 ON Selected Freeze OFF Canceled Freeze Response Unacceptable CR 9 12 4 CR_PTIMER Command Command CR_PTIMER CR Details...

Page 47: ...ver the specified temperature the sensor may show W In this case sensor 3 shows that the temperature difference is W S or N Response Unacceptable CR 9 12 7 CR_TEMPFAIL Command Command CR_TEMPFAIL CR D...