![Canon iR1020 Series Service Manual Download Page 223](http://html.mh-extra.com/html/canon/ir1020-series/ir1020-series_service-manual_59633223.webp)
Chapter 15
15-5
##0675
[Rx]
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing
the machine to release the line and suffer T1 timeout.
##0750
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-NULL, causing the procedural
signal to be transmitted more than specified.
##0752
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-NULL.
##0753
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
NULL, or T5 time-out (60 sec) has occurred.
##0754
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
NULL.
##0755
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-MPS, causing the procedural signal
to be transmitted more than specified.
##0757
[Tx]
at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
##0758
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS,
or T5 time-out (60 sec) has occurred.
##0759
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS.
##0760
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOM, causing the procedural
signal to be transmitted more than specified.
##0762
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOM.
##0763
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS,
or T5 time-out (60 sec) has occurred.
##0764
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
EOM.
##0765
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOP, causing the procedural signal
to be transmitted more than specified.
##0767
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOP.
##0768
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP,
or T5 time-out (60 sec) has occurred.
##0769
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP.
##0770
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-NULL, causing the procedural
signal to be transmitted more than specified.
##0772
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-NULL.
##0773
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
NULL, or T5 time-out (60 sec) has occurred.
##0774
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-NULL.
##0775
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-MPS, causing the procedural
signal to be transmitted more than specified.
##0777
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-MPS.
##0778
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission EOR-MPS,
or T5 time-out (60 sec) has occurred.
##0779
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-MPS.
##0780
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOM, causing the procedural
signal to be transmitted more than specified.
##0782
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOM.
##0783
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
EOM, or T5 time-out (60 sec) has occurred.
##0784
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOM.
##0785
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOP, causing the procedural
signal to be transmitted more than specified.
##0787
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOP.
##0788
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
EOP, or T5 time-out (60 sec) has occurred.
##0789
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOP.
##0790
[Rx]
at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
##0791 [Tx/Rx]
while
ECM
mode procedure is under way, a signal other than a meaningful signal is received.
##0792
[Rx]
at time of ECM reception, PPS-NULL cannot be detected over partial page processing.
##0793
[Rx]
at time of ECM reception, no effective frame is received while high-speed signal reception is under way, thus causing time-
out.
##0794
[Tx]
at time of ECM reception, PPR with all 0s is received.
##0795
[Tx/Rx]
a fault has occurred in code processing for communication.
No. Tx/Rx
Description
Summary of Contents for iR1020 Series
Page 1: ...Sep 1 2008 Service Manual iR1020 1021 1024 1025 Series ...
Page 2: ......
Page 6: ......
Page 17: ...Chapter 1 Introduction ...
Page 18: ......
Page 20: ......
Page 49: ...Chapter 1 1 29 ...
Page 50: ......
Page 51: ...Chapter 2 Installation ...
Page 52: ......
Page 54: ......
Page 61: ...Chapter 2 2 7 ...
Page 62: ......
Page 63: ...Chapter 3 Basic Operation ...
Page 64: ......
Page 66: ......
Page 73: ...Chapter 3 3 7 ...
Page 74: ......
Page 75: ...Chapter 4 Original Exposure System ...
Page 76: ......
Page 78: ......
Page 87: ...Chapter 5 Laser Exposure ...
Page 88: ......
Page 90: ......
Page 94: ......
Page 95: ...Chapter 6 Image Formation ...
Page 96: ......
Page 98: ......
Page 103: ...Chapter 7 Pickup Feeding System ...
Page 104: ......
Page 106: ......
Page 120: ......
Page 121: ...Chapter 8 Fixing System ...
Page 122: ......
Page 124: ......
Page 135: ...Chapter 9 External and Controls ...
Page 136: ......
Page 138: ......
Page 151: ...Chapter 10 Original Feeding System ...
Page 152: ......
Page 154: ......
Page 156: ...Chapter 10 10 2 M2001 ADF motor Symbol Name ...
Page 170: ......
Page 171: ...Chapter 11 e maintenance imageWARE Remote ...
Page 172: ......
Page 174: ......
Page 184: ......
Page 185: ...Chapter 12 Maintenance and Inspection ...
Page 186: ......
Page 188: ......
Page 190: ......
Page 191: ...Chapter 13 Standards and Adjustments ...
Page 192: ......
Page 194: ......
Page 201: ...Chapter 14 Correcting Faulty Images ...
Page 202: ......
Page 204: ......
Page 214: ......
Page 215: ...Chapter 15 Self Diagnosis ...
Page 216: ......
Page 218: ......
Page 224: ......
Page 225: ...Chapter 16 Service Mode ...
Page 226: ......
Page 230: ......
Page 232: ...Chapter 16 16 2 Makes various status checks such as contact sensor sensor and print status ...
Page 278: ......
Page 279: ...Chapter 17 Upgrading ...
Page 280: ......
Page 282: ......
Page 297: ...Chapter 18 Service Tools ...
Page 298: ......
Page 299: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 Special Tools 18 1 ...
Page 300: ......
Page 302: ......
Page 303: ...Sep 1 2008 ...
Page 304: ......