pg. 48
4) Install the new type of the registration assembly with the 4 screws. At this time, attach the part with
attention to the below 3 points:
[Caution]
- Attach the part so that the pin [1] of the fixing/ feeder duplexing assembly is secured in the rear hole [a] of
the registration assembly.
- Set the positioning pin [1] in the hole of the front portion of the registration assembly and attach it with the
screw.
- When installing the registration assembly, be sure to follow the order shown in the below photo for
tightening up the screws.
5) Reassemble the parts in the reverse order from the step 3).
6) Run test copy and see the jam or skewed paper does not occur any more.
[Replacement Part]
FM4-5156-010 REGISTRATION ASS'Y