pg. 93
Symptom
Image soil/smear due to the failure in installing the blade retainer
[Inspected by Canon Inc. ]
Description
Image soil or image smear appeared on a machine with a serial number earlier than the serial number
below:
Models
Serial #
Models
Serial #
iR-A 8105 V2 120V
HMU11159
iR-A 8105 V2 230V EUR
HMW01074
iR-A 8105G V2 120V
HMV10032
iR-A 8095 V2 230V EUR
HNC01073
iR-A 8095 V2 120V
HNA11788
iR-A 8085 V2 230V EUR
HNK01261
iR-A 8095G V2 120V
HNB10058
iR-A 8105 V2 230V
HMX00688
iR-A 8085 V2 120V
HNG10677
iR-A 8095 V2 230V
HND00645
iR-A 8085G V2 120V
HNH10073
iR-A 8085 V2 230V
HNL00542
iR-A 8105 V2 220V CN
HMY00521
iR-A 8095 V2 220V CN
HNE00527
Cause
Due to the backlash in the screw-tightening of the blade retainer [1] for the cleaning blade, contact failure
occurred between the cleaning blade and the drum, causing the symptom.