3) Turn the lock lever in the direction of the arrow and pull out the pre-transfer corona assembly to replace
the part.
[Caution]
- When removing the pre-transfer corona assembly, be careful not to touch the PCB [c] of the pre-transfer
corona assembly.
- Be sure to fit the pre-transfer corona assembly to the groove on the host machine and install it horizontally.
4) Reassemble the parts in the reverse order from Step2).
5) Make test copies to ensure that the machine is not jammed.
[Replacement Part]
FM3-7297 PRE-TRANSFER CORONA ASS'Y