pg. 127
Symptom
Stained image due to the separation claw contacting with the ETB
[Inspected by Canon Inc. ]
Description
With the machines from among those having serial numbers earlier than the numbers shown in the table
below, stained image occurred because the separation claw in the AP kit assembly [1] came in contact
with the ETB in the ETB assembly [3].
Model
Serial #
iR-ADV 8105 V2 120V
HMU10076
iR-ADV 8105 V2 230V EUR
HMW00790
iR-ADV 8105 V2 230V
HMX00582
iR-ADV 8105G V2 120V
HMV10004
iR-ADV 8105 V2 220V CN
HMY00505
iR-ADV 8095 V2 120V
HNA10090
iR-ADV 8095 V2 230V EUR
HNC00687
iR-ADV 8095 V2 230V
HND00561
iR-ADV 8095G V2 120V
HNB10003
iR-ADV 8095 V2 220V CN
HNE00504
iR-ADV 8085 V2 120V
HNG10037
iR-ADV 8085 V2 230V EUR
HNK00793
iR-ADV 8085 V2 230V
HNL00522
iR-ADV 8085G V2 120V
HNH10003
Cause
The separation claw [2] in the AP kit [1] which is installed to prevent paper from go into the drum may
occasionally come in contact with the ETB [4] upon a poor paper separation because the range of
movement of the separation claw is wide. The toner of the transferred image is scraped off by this
contact and the outcome image is stained. Also, when the ETB [4] is damaged or torn completely from
the contact, the image will not be transferred or jam symptoms are induced. The figure [A] shows the
contacting parts.