1001
An initialization error has occurred at the start of a job. Reset the PDL mechanism. Turn off and
then on the power.
100A
An error has occurred in the communication with an
external controller.
9004
A fault has been detected in the cable connection with
an external controller.
Turn off and then on the power. Replace
the external controller relay PCB. Replace
the
external controller.
9005
A fault has been detected in the cable connection with
an external controller.
A006
The PDL mechanism does not respond.
Reset the PDL mechanism. Turn off and
then on the power. Reinstall the system
software.
Replace the main controller.
A007
At start-up, the version of the machine control
software and that of the PDL control
software do not match.
Reset the PDL mechanism. Turn off and
then on the power. Execute full formatting
of the
HDD, and reinstall the system software.
B013
The font data is corrupted at start-up.
Turn off and then on the power. Reinstall
the system software. Execute full
formatting of
the HDD, and reinstall the system
software.
E732
An error has occurred in the communication between the reader unit and the main
controller.
0001
An error has occurred in the communication between
the reader unit and the main
controller.
Disconnect and connect the connectors of
the read communication cable. Check the
power supply of the reader unit (to see if
initialization occurs at power-on). Replace
the
reader controller PCB. Reap the reader I/F
PCB. Replace the main controller PCB.
0010
A fault has been detected in the reader sync signal
detection mechanism.
E733
An error has occurred in the communication between the reader unit and the main
controller.
0000
An error has occurred in the communication between
the reader unit and the main
controller.
Disconnect and then connect the
connector. Check the power supply of the
DC controller (to
see if initialization occurs at time of start-
up). Replace the DC controller PCB.
Replace the
main controller PCB.
0001
An attempt to communicate with the DC controller
fails.
0010
A fault has occurred in the printer engine sync signal
detection mechanism.
E740
An error exists in the LAN controller.
0002
An illegal MAC address has been detected at start-up. Replace the main controller PCB.
E743
A fault exists in the communication between the main controller and the reader controller.
0000
The reader controller has detected an error in the
communication between the main
controller and the reader controller.
Disconnect and then connect the
connectors of the reader communications
cable. Replace
the reader controller PCB. Replace the
main controller PCB.
E744
An error exists in the language file/boot ROM.
Code
Description
Remedial action
*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).
**: model equipped with DADF-M1 (outside Japan: iR7086).
Summary of Contents for IMAGERUNNER 7086
Page 20: ...Chapter 1 Introduction ...
Page 46: ...Chapter 2 Installation ...
Page 88: ...Chapter 3 Basic Operation ...
Page 94: ...Chapter 4 Main Controller ...
Page 116: ...Chapter 5 Original Exposure System ...
Page 165: ...Laser Exposure Chapter 6 ...
Page 175: ...Chapter 7 Image Formation ...
Page 231: ...Chapter 8 Pickup Feeding System ...
Page 287: ...Chapter 9 Fixing System ...
Page 312: ...Chapter 10 External and Controls ...
Page 346: ...Chapter 11 MEAP ...
Page 350: ...Chapter 12 RDS ...
Page 360: ...Chapter 13 Maintenance Inspection ...
Page 375: ...Chapter 14 Standards Adjustments ...
Page 407: ...Chapter 15 Correcting Faulty Images ...
Page 433: ...Chapter 16 Self Diagnosis ...
Page 460: ...Chapter 17 Service Mode ...
Page 559: ...Chapter 18 Upgrading ...
Page 583: ...Chapter 19 Service Tools ...
Page 588: ...APPENDIX ...
Page 615: ......