Chapter 7
7-5
7.4.2 Basics Sequence of Operations
0010-8040
The following shows the basic sequence of operations and timing of operations associated with the ma-
chine's control system:
F-7-5
F-7-6
SERVICE MODE:
- COPIER> OPTION> BODY> PO-CNT
(enabling/disabling potential control)
0: potential control OFF
1: potential control ON (default)
-
COPIER> ADJUST> V-CONT> EPOTOFST
(potential sensor offset value input)
If the DC controller PCB has been replaced or the RAM on the DC controller PCB has been initialized,
enter the value indicated on the service label.
-
COPIER> ADJUST> V-CONT> VL-OFST
(VL target potential offset value input)
If the DC controller PCB has been replaced or the RAM on the DC controller PCB has been initialized,
enter the value indicated on the service label.
-
COPIER> ADJUST> V-CONT> VD-OFST
(VD target potential offset value input)
If the DC controller PCB has been replaced or the RAM on the DC controller has been initialized, enter
the value indicated on the service label.
-
COPIER> FUNCTION> DPC> OFST
(potential sensor offset adjustment)
This mode item is part of the series of procedures that must be performed when the potential sensor unit
is replaced. It is not performed on its own.
WMUPR
WMUP
STBY
193
198
Drum motor(M0)
Primary charging bias(DC)
Developing bias(AC)
Developing bias(DC)
Grid bias
Laser
Potential stabilization sequence
Potential control
Potential control for
transparency mode
Optimum grid
bias determined
Optimum laser
output determined
Optimum laser
output determined
Fixed value
Performs a series of charging operations to stabilize the drum potential.
Uses the potential control mechanism that is used
when the main power switch is turned on.
60 min later
Potential
control
Potential
control
Potential
control
Potential control
for transparency
Main power
switch ON
Fixing assembly temperature
(end of fixing assembly warm-up)
[1] The control panel power switch is turned on.
[2] The front door is opened/closed.
Start key ON
Start key ON
10 min later
1 hr later
Starting when the fixing assembly temperature reaches 193 deg C,
executes potential control every 10 min and 60 min.
After previous potential control,
executes potential control every hour.
Potential
control
Summary of Contents for IMAGERUNNER 7086
Page 20: ...Chapter 1 Introduction ...
Page 46: ...Chapter 2 Installation ...
Page 88: ...Chapter 3 Basic Operation ...
Page 94: ...Chapter 4 Main Controller ...
Page 116: ...Chapter 5 Original Exposure System ...
Page 165: ...Laser Exposure Chapter 6 ...
Page 175: ...Chapter 7 Image Formation ...
Page 231: ...Chapter 8 Pickup Feeding System ...
Page 287: ...Chapter 9 Fixing System ...
Page 312: ...Chapter 10 External and Controls ...
Page 346: ...Chapter 11 MEAP ...
Page 350: ...Chapter 12 RDS ...
Page 360: ...Chapter 13 Maintenance Inspection ...
Page 375: ...Chapter 14 Standards Adjustments ...
Page 407: ...Chapter 15 Correcting Faulty Images ...
Page 433: ...Chapter 16 Self Diagnosis ...
Page 460: ...Chapter 17 Service Mode ...
Page 559: ...Chapter 18 Upgrading ...
Page 583: ...Chapter 19 Service Tools ...
Page 588: ...APPENDIX ...
Page 615: ......