Chapter 5
5-36
2) Remove the 4 screws [1], and detach the
reinforcing plate [2].
F-5-110
3) Remove the hook, and detach the ADF open/
closed sensor (1, 2).
F-5-111
5.4.10 Original Size Sensor
5.4.10.1 Before Starting the Work
0011-9312
1) Remove the copyboard glass.
2) Remove the CCD unit cover [1].
- 9 screws [2]
F-5-112
3) Remove the original size sensor unit.
5.4.10.2 Removing the Original Size
Sensor Unit
0011-7967
1) Remove the 3 screws [1], and shift the original
size detection unit [2].
F-5-113
2) Disconnect the connector [1], and detach the
original size sensor unit [2].
F-5-114
5.4.10.3 Removing the Original Size
Sensor
0011-7968
1) While releasing the claw at the end, detach the
original size sensor [1].
F-5-115
[1]
[1]
[2]
[1]
[1]
[2]
[2]
[2]
[2]
[1]
[1]
[2]
[1]
[2]
[1]
Summary of Contents for IMAGERUNNER 7086
Page 20: ...Chapter 1 Introduction ...
Page 46: ...Chapter 2 Installation ...
Page 88: ...Chapter 3 Basic Operation ...
Page 94: ...Chapter 4 Main Controller ...
Page 116: ...Chapter 5 Original Exposure System ...
Page 165: ...Laser Exposure Chapter 6 ...
Page 175: ...Chapter 7 Image Formation ...
Page 231: ...Chapter 8 Pickup Feeding System ...
Page 287: ...Chapter 9 Fixing System ...
Page 312: ...Chapter 10 External and Controls ...
Page 346: ...Chapter 11 MEAP ...
Page 350: ...Chapter 12 RDS ...
Page 360: ...Chapter 13 Maintenance Inspection ...
Page 375: ...Chapter 14 Standards Adjustments ...
Page 407: ...Chapter 15 Correcting Faulty Images ...
Page 433: ...Chapter 16 Self Diagnosis ...
Page 460: ...Chapter 17 Service Mode ...
Page 559: ...Chapter 18 Upgrading ...
Page 583: ...Chapter 19 Service Tools ...
Page 588: ...APPENDIX ...
Page 615: ......