Chapter 5
5-10
F-5-19
ERROR CODE:
E202 (HP detection error)
-0001: when the No. 1 mirror base is moving forward, it fails to reach the HP sensor within a specific
period of time
-0002: when the No. 1 mirror base is moving in reverse, it fails to reach the HP sensor within a specific
period of time
SERVICE MODE:
COPIER>ADJUST>ADJ-XY>ADJ-X (scanner image leading edge position adjustment)
Enter a value to adjust the image leading edge position.
settings range: 0 to 2970 (a change of '12' causes a shift of 1 mm)
COPIER>AJST>ADJ-XY>ADJ-S
(scanner home position)
Do not change the setting.
5.3.2 Enlargement/Reduction
5.3.2.1 Changing the Reproduction Ratio in Main Scanning Direction
0010-7889
To change the magnification in main scanning direction (for both platen and ADF modes), the machine
reads the image at 100% and applies appropriate image processing in the main controller block.
5.3.2.2 Changing the Reproduction Ratio in Sub Scanning Direction <iR7105/7095>
0010-7890
To execute scaling, the moving speed of the mirror 1 mount is changed.
Also, digital scaling is concurrently used under the following conditions:
- Fixed reading: scaling is from 25 to 99.9%
- Stream reading: scaling is from 25 to 88.9%
MEMO:
Stream reading is basically executed when a copy is made with the ADF. However,
fixed reading is executed instead if scaling is from 25 to 49.9% or a 2-sided copy is made at any scaling
factor. Fixed reading is executed whenever a copy is made in book mode.
5.3.2.3 Changing the Reproduction Ratio in Sub Scanning Direction <iR7086>
0011-2185
To execute scaling, the moving speed of the mirror 1 mount is changed.
Also, digital scaling is concurrently used under the following conditions:
- Fixed reading: scaling is from 25 to 99.9%
- Stream reading: scaling is from 25 to 50%
Start
position
Acceleration
Image leading edge
Constant speed
Image trailing edge
Deceleration
Stop
Shift
speed
Shift distance
[1]
[2]
[3]
[4]
[1] Acceleration interval: accelerates up to scan speed
[2] Run-up interval: run-up margin used to ensure stable speed
[3] Image read interval: segment over which images are read
[4] Deceleration interval: at the image trailing edge, decelerates and stops as soon as possible
HP
Summary of Contents for IMAGERUNNER 7086
Page 20: ...Chapter 1 Introduction ...
Page 46: ...Chapter 2 Installation ...
Page 88: ...Chapter 3 Basic Operation ...
Page 94: ...Chapter 4 Main Controller ...
Page 116: ...Chapter 5 Original Exposure System ...
Page 165: ...Laser Exposure Chapter 6 ...
Page 175: ...Chapter 7 Image Formation ...
Page 231: ...Chapter 8 Pickup Feeding System ...
Page 287: ...Chapter 9 Fixing System ...
Page 312: ...Chapter 10 External and Controls ...
Page 346: ...Chapter 11 MEAP ...
Page 350: ...Chapter 12 RDS ...
Page 360: ...Chapter 13 Maintenance Inspection ...
Page 375: ...Chapter 14 Standards Adjustments ...
Page 407: ...Chapter 15 Correcting Faulty Images ...
Page 433: ...Chapter 16 Self Diagnosis ...
Page 460: ...Chapter 17 Service Mode ...
Page 559: ...Chapter 18 Upgrading ...
Page 583: ...Chapter 19 Service Tools ...
Page 588: ...APPENDIX ...
Page 615: ......